Evaluation of right ventricular function and post-operative findings using cardiac computed tomography in patients with left ventricular assist devices

Fecha de publicación:

Autores de IDIVAL

  • Leticia Fernandez Friera

    Autor

Autores ajenos al IDIVAL

  • Garcia-Alvarez A
  • Lau JF
  • Sawit ST
  • Mirelis JG
  • Castillo JG
  • Pinney S
  • Anyanwu AC
  • Fuster V
  • Sanz J
  • Garcia MJ

Abstract

BACKGROUND: Right ventricular (RV) failure is a major contributor to morbidity and mortality after left ventricular assist device (LVAD) implantation. Accurate evaluation of RV function in patients with LVAD remains challenging. We hypothesized that, after LVAD implantation, electrocardiographicgated cardiac computed tomography (CCT) allows RV evaluation with higher feasibility and reproducibility compared with echocardiography. METHODS: Thirty-six patients with an implanted LVAD who had 2-dimensional echocardiography and CCT evaluation were studied. RV end-diastolic and end-systolic volumes and ejection fraction were quantified using CCT. RV fractional area change, tricuspid annular plane systolic excursion and RV end-diastolic short-to-long axis ratio were calculated by echocardiography. Intraclass correlation coefficients (ICCs) and Bland-Altman analysis were used to assess intra- and interobserver reproducibility for all measurements. RESULTS: The quality of CCT studies was good in all cases except for one. Intra- and interobserver reproducibility for all CCT measurements was high (interobserver ICC for RV ejection fraction = 0.89, 95% confidence interval 0.74 to 0.95). Echocardiographic indices of RV function and geometry had lower reproducibility. The echocardiographic index that best correlated with the CCT-determined RV ejection fraction was RV fractional area change (r = 0.80, p < 0.001). In addition, CCT detected relevant post-operative findings in 50% of the patients. CONCLUSIONS: CCT is highly effective and reproducible compared with echocardiography for the evaluation of RV function in patients with LVAD support and provides relevant information on post-operative findings. Our results suggest that CCT should be considered as a useful imaging modality in this clinical setting. J Heart Lung Transplant 2011;30:896-903 (C) 2011 International Society for Heart and Lung Transplantation. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
1053-2498, 1557-3117

JOURNAL OF HEART AND LUNG TRANSPLANTATION  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
896-903
PubMed:
21530319

Citas Recibidas en Web of Science: 28

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Campos de Estudio

Cita

Compartir