Early planar and early SPECT Tc-99m sestamibi imaging: can it replace the dual-phase technique for the localization of parathyroid adenomas by omitting the delayed phase?
Autores de IDIVAL
Abstract
To evaluate whether an early protocol (EP) (early planar and early SPECT) with Tc-99m sestamibi could demonstrate the delayed image of the established dual-phase scintigraphy unnecessary without any decrease in sensitivity for the localization of parathyroid adenomas.
Datos de la publicación
- ISSN/ISSNe:
- 0363-9762, 1536-0229
- Tipo:
- Article
- Páginas:
- 749-753
- PubMed:
- 21825841
CLINICAL NUCLEAR MEDICINE LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 10
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- hyperparathyroidism; Tc-99m sestamibi scintigraphy; SPECT; parathyroid adenoma; minimally invasive parathyroidectomy
Campos de Estudio
Cita
Martínez I, Banzo I, Quirce R, Jiménez J, Portilla H, Medina P, De Arcocha M, Carril JM. Early planar and early SPECT Tc-99m sestamibi imaging: can it replace the dual-phase technique for the localization of parathyroid adenomas by omitting the delayed phase?. Clin. Nucl. Med. 2011. 36. (9):p. 749-753. IF:3,766. (1).
Actividad Investigadora