Implantation of a Drug-Eluting Stent With a Different Drug (Switch Strategy) in Patients With Drug-Eluting Stent Restenosis Results From a Prospective Multicenter Study (RIBS III [Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-Eluting Stent])
Fecha de publicación:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Alfonso F
- Pérez-Vizcayno MJ
- Dutary J
- Cequier A
- García-Touchard A
- Martí V
- Lozano I
- Angel J
- Hernández JM
- López-Mínguez JR
- Melgares R
- Moreno R
- Seidelberger B
- Fernández C
- Hernandez R
Unidades
Abstract
Objectives This study sought to assess the effectiveness of a strategy of using drug-eluting stents (DES) with a different drug (switch) in patients with DES in-stent restenosis (ISR). Background Treatment of patients with DES ISR remains a challenge. Methods The RIBS-III (Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-Eluting Stent) study was a prospective, multicenter study that aimed to assess results of coronary interventions in patients with DES ISR. The use of a different DES was the recommended strategy. The main angio-graphic endpoint was minimal lumen diameter at 9-month follow-up. The main clinical outcome measure was a composite of cardiac death, myocardial infarction, and target lesion revascularization. Results This study included 363 consecutive patients with DES ISR from 12 Spanish sites. The different-DES strategy was used in 274 patients (75%) and alternative therapeutic modalities (no switch) in 89 patients (25%). Baseline characteristics were similar in the 2 groups, although lesion length was longer in the switch group. At late angiographic follow-up (77% of eligible patients, median: 278 days) minimal lumen diameter was larger (1.86 +/- 0.7 mm vs. 1.40 +/- 0.8 mm, p = 0.003) and recurrent restenosis rate lower (22% vs. 40%, p = 0.008) in the different-DES group. At the last clinical follow-up (99% of patients, median: 771 days), the combined clinical endpoint occurred less frequently (23% vs. 35%, p = 0.039) in the different-DES group. After adjustment using propensity score analyses, restenosis rate (relative risk: 0.41, 95% confidence interval [CI]: 0.21 to 0.80, p = 0.01), minimal lumen diameter (difference: 0.41 mm, 95% CI: 0.19 to 0.62, p = 0.001), and the event-free survival (hazard ratio: 0.56, 95% CI: 0.33 to 0.96, p = 0.038) remained significantly improved in the switch group. Conclusions In patients with DES ISR, the implantation of a different DES provides superior late clinical and angiographic results than do alternative interventional modalities. (J Am Coll Cardiol Intv 2012;5:728-37) (C) 2012 by the American College of Cardiology Foundation
Datos de la publicación
- ISSN/ISSNe:
- 1936-8798, 1876-7605
- Tipo:
- Article
- Páginas:
- 728-737
- PubMed:
- 22814777
JACC-CARDIOVASCULAR INTERVENTIONS ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 88
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- different stent; drug-eluting stents; in-stent restenosis; switch strategy
Campos de Estudio
Cita
Alfonso F, Pérez MJ, Dutary J, Zueco J, Cequier A, García A, Martí V, Lozano I, Angel J, Hernández JM, López JR, Melgares R, Moreno R, Seidelberger B, Fernández C, Hernandez R. Implantation of a Drug-Eluting Stent With a Different Drug (Switch Strategy) in Patients With Drug-Eluting Stent Restenosis Results From a Prospective Multicenter Study (RIBS III [Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-Eluting Stent]). JACC Cardiovasc Interv. 2012. 5. (7):p. 728-737. IF:6,800. (1).
Actividad Investigadora