Comparison of (99)mTc-sestamibi and C-11-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • María Isabel Martínez Rodríguez

    Autor

  • Néstor Anibal Martínez Amador

    Autor

  • María De Arcocha Torres

    Autor

  • María De Los Remedios Quirce Pisano

    Autor

  • Fernando Ortega Nava

    Autor

  • Susana Marlen Ibañez Bravo

    Autor

  • María Del Carmen Lavado Pérez

    Autor

  • Zully Del Carmen Bravo Ferrer

    Autor

  • José Manuel Carril Carril

    Autor

Abstract

Aim: To evaluate the usefulness of C-11-methionine PET/CT (MET) in the localization of the parathyroid adenomas and to compare the results with those obtained with the conventional technique in double-phase Tc-99m-sestamibi scintigraphy (MIBI). We evaluated the optimal timing to acquire MET images. Material and methods: A prospective study that included 14 patients (mean age: 65.5 +/- 9.7 years) with primary hyperparathyroidism (PH) who underwent surgery was performed. Mean serum iPTH was 215.8 +/- 108 pg/mL and serum calcium 10.8 +/- 0.9 mg/dL. MIBI (planar and SPECT) was obtained 10 min and 2-3 h after injection of 740 MBq (20 mCi) of Tc-99m-sestamibi. MET was obtained 10 min and 40 min after injection of 740 MBq (20 mCi) of C-11-methionine. MIBI and MET images were visually evaluated and compared. A score for 10 min and 40 min MET images from 0 (no abnormal uptake) to 3 (intense uptake) was assigned. Results: MIBI and MET were positive and concordant in 11/14 patients and in 10 of them the parathyroid adenoma was correctly localized. In 3/14 MIBI was positive and MET negative (MIBI correctly localized the parathyroid adenoma in 2 of them). According to the timing of MET imaging acquisition, the 10 min and 40 min acquisition showed the same score in 10 patients, it was higher at 10 min acquisition in 3 and in 1 the parathyroid adenoma was only detected at 40 min acquisition. Conclusion: MIBI remains the technique of choice for the localization of parathyroid adenomas in patients with PH. MET may play a complementary role in selected patients. Delayed acquisition should be included in the MET protocol when the early acquisition is negative. (C) 2013 Elsevier Espana, S.L. and SEMNIM. All rights reserved.

Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
2253-654X, 2253-8070

Revista Espanola de Medicina Nuclear e Imagen Molecular  ELSEVIER ESPANA SLU

Tipo:
Article
Páginas:
93-98
PubMed:
24125595

Citas Recibidas en Web of Science: 13

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • C-11-methionine PET/CT; Tc-99m-sestamibi scintigraphy; Parathyroid adenoma; Primary hyperparathyroidism; Minimally invasive surgery

Campos de Estudio

Cita

Compartir