Disfunción por trombosis en bioprótesis de Hancock mitral resuelta con heparina.
Autores de IDIVAL
Autores ajenos al IDIVAL
- Moujir F
- Trugeda A
Abstract
Thrombotic malfunction is a rare and shortly documented complication of cardiac bioprostheses. Surgical treatment is usually needed. We report a patient with thrombotic occlusion of a Hancock mitral prosthesis which was resolved with heparin. Clinical and therapeutic features are discussed. To our knowledge, this is the first case of a bioprosthetic thrombotic obstruction successfully managed with heparin therapy.
Datos de la publicación
- ISSN/ISSNe:
- 0300-8932, 1579-2242
- Tipo:
- Abstract of Published Item
- Páginas:
- 219-221
- PubMed:
- 2781117
REVISTA ESPANOLA DE CARDIOLOGIA EDICIONES DOYMA S A
Documentos
- No hay documentos
Métricas
Filiaciones
Filiaciones no disponibles
Cita
Moujir F, Martín R, Vázquez de Prada JA, Trugeda A, Figueroa A, Olalla JJ. Disfunción por trombosis en bioprótesis de Hancock mitral resuelta con heparina. Rev. Esp. Cardiol. 1989. 42(3):p. 219-221.