Utility of home oximetry as a screening test for patients with moderate to severe symptoms of obstructive sleep apnea

Fecha de publicación:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Golpe, R
  • Jimenez, A
  • Carpizo, R

Abstract

Objective: To determine the value of home oximetry as a screening test in patients with moderate to severe symptoms of obstructive sleep apnea (OSA). Design: Retrospective, observational study. Setting: The Sleep Unit of a tertiary referral, university hospital. Patients: 116 patients referred for evaluation of moderate to severe symptoms of OSA in which both home oximetry and polysomnography (PSG) were performed. Interventions: NA Results: Three numerical oximetry indices were evaluated: average of desaturations greater than or equal to 4% and average of resaturations greater than or equal to 3% per hour of analysis time (DI4% and RI3%, respectively); and cumulative percentages of time spent at saturations below 90% (CT90%). A qualitative assessment was also performed. Oximetry indices were compared with apnea/hypopnea index (AHI) by simple linear regression and Bland-Altman analyses. Optimal cut-off points, in terms of sensitivity and specificity, for the oximetry indices were searched using ROC analysis, at an AHI threshold of greater than or equal to 10. The correlation between AHI and the desaturation indices was r=0.50 for CT90%, r=0.60 for DI4%, and r=0.58 for RI3%. No bias was found between PSG and oximetry indices in Bland-Altman plots. Neither the numerical indices nor the qualitative analysis achieved an adequate (> 0.8) area under the ROC curve. A CT90% <0.79 excluded OSA with 84% sensitivity. A DI4% greater than or equal to 31.4 or a RI3% greater than or equal to 40.5 diagnosed OSA with 97% specificity. Using these values, 38% of the patients would have been correctly classified by oximetry alone, 10% would have been incorrectly classified, and 50% could not have been classified with certainty. Eleven (15%) OSA patients would have been missed by oximetry. Conclusions: Correlation between home oximetry and PSG was not high. Oximetry was more useful to confirm than to exclude OSA in our study. Qualitative assessment was not better than numerical analysis. The greatest value of oximetry in this setting seems to be as a tool to rapidly recognize and treat more severe OSA patients in waiting list for PSG.

Datos de la publicación

ISSN/ISSNe:
0161-8105, 1550-9109

SLEEP  OXFORD UNIV PRESS INC

Tipo:
Article
Páginas:
932-937
DOI:
PubMed:
10566911

Citas Recibidas en Web of Science: 96

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Keywords

  • sleep apnea syndromes, oximetry, polysomnography

Cita

Compartir