Two-year clinical follow-up in 200 patients receiving sirolimus-eluting stents in lesions at a high risk of restenosis

Fecha de publicación:

Autores de IDIVAL

  • José María De La Torre Hernández

    Autor

  • Fermín Sainz Laso

    Autor

  • Miguel Fernando Llano Cardenal

    Autor

  • Marta Ruiz Lera

    Autor

  • Leticia Fernandez Friera

    Autor

  • Virginia Burgos Palacios

    Autor

  • José Javier Zueco Gil

    Autor

  • Alvaro Figueroa Olavarria

    Autor

  • Thierry Colman Dejean

    Autor

Abstract

Introduction and objectives. Sirolimus-eluting stents (SESs) have been shown to reduce the rate of restenosis significantly in all types of coronary lesion. However, reports of late cases of thrombosis and restenosis have raised questions about long-term outcome in patients treated with these stents. Our aim was to evaluate long-term outcome in patients undergoing SES placement in lesions at a high risk of restenosis. Patients and method. Since SESs became available, we have used them to treat lesions at risk of restenosis. We studied clinical outcomes in consecutive patients treated with SESs who were followed up for more than 2 years. Results. The study included 200 patients (age 60[11] years, 22% diabetics) who were treated between June 2002 and April 2003 for 309 lesions: 16% were total occlusions, 16.8% in-stent restenoses, 28% diffuse lesions, and 30% small-vessel lesions. The total stent length per patient was 29 (16) mm and the mean diameter was 2.78 (0.27) mm. In a mean clinical follow-up period of 29 (3.2) months (range 24-34 months), there were four deaths, two (1%) of which were cardiac, four (2%) non-fatal infarctions, four (2%) in-stent thromboses (all occurred late, at 3, 7, 26 and 31 months), four (2%) cases requiring target lesion revascularization (at 3, 5, 14 and 15 months), and six (3%) requiring revascularization of a new lesion. Conclusions. Long-term follow-up of patients undergoing SES placement in lesions at a high risk of restenosis revealed a very low restenosis rate. However, the incidence of late thrombosis appeared to be elevated and warrants further evaluation in larger studies.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
225-231
PubMed:
16712746

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Cita

Compartir