Treatment of lesions with a high risk of stenosis. Comparative study in 300 patients of rapamycin and paclitaxel-eluting polymer-based stents, and bare metal stents

Fecha de publicación:

Autores de IDIVAL

  • José María De La Torre Hernández

    Autor

  • Fermín Sainz Laso

    Autor

  • Cristina Ruisánchez Villar

    Autor

  • José Javier Zueco Gil

    Autor

  • Alvaro Figueroa Olavarria

    Autor

  • Thierry Colman Dejean

    Autor

Abstract

Introduction and objectives. Rapamycin- and taxoleluting stents have been shown to reduce restenosis, but there are no large-scale studies of their usefulness in lesions with a high risk of restenosis, or of the relative merits of the two devices. This prospective study compared their safety and efficacy in lesions with a high risk of restenosis. Patients and method. We included consecutive patients with lesions to treat that met at least one of the following criteria: a) in-stent restenosis; b) diffuse (> 20 mm) restenosis; c) small vessel (<= 2,5 mm) restenosis; or d) total occlusion. Patients received different devices along three consecutive study periods: bare metal (conventional) stents, sirolimus-eluting (rapamycin) stents; and paclitaxel-eluting (taxol) stents. Results. One hundred patients in each group were included, for a total of 300 patients. In the sirolimus group, after 8.5 +/- 2 months of follow-up, there were 2 late thromboses (2%) and only 1 patient (1%) required target lesion revascularization. In the paclitaxel group 2 patients (2%) had in-hospital stent thrombosis (1 acute, 1 subacute), and after 9 +/- 2.5 months of follow-up only 1 patient (11%) needed target lesion revascularization. In the conventional group, after 8 2 months of follow-up, there was 1 subacute thrombosis (1%) and 15 patients (15%) had clinical restenosis; requiring target lesion revascularization. Event-free survival curves were significantly better with drug-eluting stents (P < 01 vs conventional stents). Conclusion. Rapamycin- and taxol-eluting stents were safe for lesions with a high risk of restenosis. These stents were associated with a lower rate of target lesion revascularization during follow-up compared to bare metal stents.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
262-269
DOI:
PubMed:
15766448

Citas Recibidas en Web of Science: 7

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Cita

Compartir