Intravascular ultrasonographic evaluation of direct stents, implanted without predilatation. Comparison of results according to lesion types

Fecha de publicación:

Autores de IDIVAL

  • José Javier Zueco Gil

    Autor

  • Alvaro Figueroa Olavarria

    Autor

  • Thierry Colman Dejean

    Autor

Autores ajenos al IDIVAL

  • Hernandez, JMD
  • Gonzalez, IG
  • Entem, FR
  • Royuela, N
  • Juarez, FMA

Abstract

Introduction. Direct stenting is a safe and feasible technique in selected lesions yielding excellent angiographic results. However, there are no studies providing intravascular ultrasonographic examination after direct stenting. The aim of this study was to evaluate direct stent expansion with ultrasonography and to know whether there are differences in the results based on lesion types. Methods. Patients with amenable lesions for direct stenting were enrolled; including patients with no occlusion, no calcification, no significant tortuosity or angulation, a length less than or equal to 15 mm and a reference lumen diameter greater than or equal to2.5 mm. Intra vascular ultrasonography was performed after stent implantation. The ultrasonographic criteria for optimal expansion were: complete apposition and a minimal intrastent lumen area >80% of the average reference luminal area and greater than or equal to 90% of the distal reference lumen area. Results. We included 40 patients (50 lesions). The final angiographic result was good in all the patients but in one case an additional stent was used due to dissection. The ultrasonographic examination did not show significant differences between type A and B lesions. Optimal expansion was achieved in 14/21 (66%) of type A lesions and 17/29 (58%) of type B lesions (p = 0.5). The balloon/artery ratio was the only factor significantly related to ultrasonographic results. When this ratio was 1.1-1.2 (25 cases), 76% of the stents were optimally expanded and when the ratio was <1.1 (25 cases) only in a 48% an optimal result was achieved (p < 0.05). Conclusions. Direct stenting in selected lesions provides ultrasonographic results comparable to those expected with conventional stenting and these results could be even improved if a balloon artery ratio 1.1-1.2 is used. Taking into consideration the selection criteria the differences observed between lesion types A and B are not significant.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
1335-1341
DOI:
PubMed:
11061714

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Cita

Compartir