Efficacy of Home Single-Channel Nasal Pressure for Recommending Continuous Positive Airway Pressure Treatment in Sleep Apnea

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Masa, JF
  • Duran-Cantolla, J
  • Capote, F
  • Abad, J
  • Garcia-Rio, F
  • Ferrer, A
  • Fortuna, AM
  • Gonzalez-Mangado, N
  • de la Pena, M
  • Aizpuru, F
  • Barbe, F
  • Montserrat, JM
  • Spanish Sleep Network

Abstract

Introduction: Unlike other prevalent diseases, obstructive sleep apnea (OSA) has no simple tool for diagnosis and therapeutic decision-making in primary healthcare. Home single-channel nasal pressure (HNP) may be an alternative to polysomnography for diagnosis but its use in therapeutic decisions has yet to be explored. Objectives: To ascertain whether an automatically scored HNP apnea-hypopnea index (AHI), used alone to recommend continuous positive airway pressure (CPAP) treatment, agrees with decisions made by a specialist using polysomnography and several clinical variables. Methods: Patients referred by primary care physicians for OSA suspicion underwent randomized polysomnography and HNP. We analyzed the total sample and both more and less symptomatic subgroups for Bland and Altman plots to explore AHI agreement; receiver operating characteristic curves to establish area under the curve (AUC) measurements for CPAP recommendation; and therapeutic decision efficacy for several HNP AHI cutoff points. Results: Of the 787 randomized patients, 35 (4%) were lost, 378 (48%) formed the more symptomatic and 374 (48%) the less symptomatic subgroups. AHI bias and agreement limits were 5.8 +/- 39.6 for the total sample, 5.3 +/- 38.7 for the more symptomatic, and 6 +/- 40.2 for the less symptomatic subgroups. The AUC were 0.826 for the total sample, 0.903 for the more symptomatic, and 0.772 for the less symptomatic subgroups. In the more symptomatic subgroup, 70% of patients could be correctly treated with CPAP. Conclusion: Automatic home single-channel nasal pressure scoring can correctly recommend CPAP treatment in most of more symptomatic patients with OSA suspicion. Our results suggest that this device may be an interesting tool in initial OSA management for primary care physicians, although future studies in a primary care setting are necessary.

© 2014 Associated Professional Sleep Societies, LLC.

Datos de la publicación

ISSN/ISSNe:
0161-8105, 1550-9109

SLEEP  OXFORD UNIV PRESS INC

Tipo:
Article
Páginas:
11-21
PubMed:
25325508

Citas Recibidas en Web of Science: 14

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Apnealink; CPAP; portable monitor; sleep apnea

Cita

Compartir