The routine use of surgical exposure approach for trans-femoral implantation of the balloon expandable aortic prosthesis is associated to a low rate of vascular complications
Autores de IDIVAL
Autores ajenos al IDIVAL
- Moreno, R
- Garcia Del Blanco, B
- San Martin JC
- Serra Garcia V
- Gaviria K
- Garcia Blas S
- Garcia, I
Unidades
Abstract
BACKGROUND: The most frequent complications of transfemoral aortic valve implantation are vascular (15-25%) and are related to an increase in mortality. We sought to assess the rate of vascular complications, its treatment and outcomes using a surgical approach for transfemoral implantation of Edwards-SAPIEN (Edwards Lifescience, Irvine, CA, USA) aortic valve. METHODS: We have conducted a multicenter registry including 4 hospitals using a systematic surgical exposure approach. Vascular complications have been collected following the definitions of the Valve Academic Research Consortium. RESULTS: From 2008 to 2013 a total of 312 consecutive patients have been included. Vascular complications were reported in 22 (7%), among those 6 (1.9%) were major whereas 16 (5.1%) were minor. Patients suffering vascular complications had significantly more previous history of peripheral vascular disease. All but one major complications occurred in women, aged 82-88 and with chronic renal failure. Hospital stay was longer in cases suffering complications (17.8 +/- 11 days vs. 9 +/- 7 days; P<0.0001). The 30 days mortality was 13.6% in patients with vascular complications, 33.3% in patients with major complications and 5.5% in patients with no complications (P=0.05). CONCLUSIONS: In this registry, the systematic use of a surgical exposure of the femoral artery for TAVR has been associated with a lower rate of vascular complications.
Datos de la publicación
- ISSN/ISSNe:
- 0021-9509, 1827-191X
- Tipo:
- Article
- Páginas:
- 615-619
- PubMed:
- 25673098
JOURNAL OF CARDIOVASCULAR SURGERY EDIZIONI MINERVA MEDICA
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Métricas
Filiaciones
Keywords
- Aortic valve stenosis; Transcatheter aortic valve implantation; Femoral artery
Campos de Estudio
Cita
de la Torre JM, Moreno R, Lee DH, Garcia Del Blanco B, San Martin JC, Serra V, Gaviria K, Garcia S, Garcia I, Zueco J. The routine use of surgical exposure approach for trans-femoral implantation of the balloon expandable aortic prosthesis is associated to a low rate of vascular complications. J. Cardiovasc. Surg. 2016. 57. (4):p. 615-619. IF:1,632. (3).
Actividad Investigadora