A Prospective Randomized Trial of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis of Drug-Eluting Stents The RIBS IV Randomized Clinical Trial

Fecha de publicación:

Autores de IDIVAL

  • José Javier Zueco Gil

    Autor

Autores ajenos al IDIVAL

  • Alfonso, F
  • Perez-Vizcayno, MJ
  • Cardenas, A
  • del Blanco, BG
  • Garcia-Touchard, A
  • Lopez-Minguez, JR
  • Benedicto, A
  • Masotti, M
  • Iniguez, A
  • Velazquez, M
  • Moreno, R
  • Mainar, V
  • Dominguez, A
  • Pomar, F
  • Melgares, R
  • Rivero, F
  • Jimenez-Quevedo, P
  • Gonzalo, N
  • Fernandez, C
  • Macaya, C
  • RIBS IV Study Investigators
  • Spanish Soc Cardiology

Unidades

Abstract

BACKGROUND Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) remains a major challenge. OBJECTIVES This study evaluated the comparative efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients presenting with DES-ISR. METHODS The study design of this multicenter randomized clinical trial assumed superiority of EES for the primary endpoint, in-segment minimal lumen diameter at the 6- to 9-month angiographic follow-up. RESULTS A total of 309 patients with DES-ISR from 23 Spanish university hospitals were randomly allocated to DEB (n = 154) or EES (n = 155). At late angiography (median 247 days; 90% of eligible patients), patients in the EES arm had a significantly larger minimal lumen diameter (2.03 +/- 0.7 mm vs. 1.80 +/- 0.6 mm; p < 0.01) (absolute mean difference: 0.23 mm; 95% CI: 00.7 to 0.38), net lumen gain (1.28 +/- 0.7 mm vs. 1.01 +/- 0.7 mm; p < 0.01), and lower percent diameter stenosis (23 +/- 22% vs. 30 +/- 22%; p < 0.01) and binary restenosis rate (11% vs. 19%; p = 0.06), compared with patients in the DEB arm. Consistent results were observed in the in-lesion analysis. At the 1-year clinical follow-up (100% of patients), the main clinical outcome measure (composite of cardiac death, myocardial infarction, and target vessel revascularization) was significantly reduced in the EES arm (10% vs. 18%; p = 0.04; hazard ratio: 0.58; 95% CI: 0.35 to 0.98), mainly driven by a lower need for target vessel revascularization (8% vs. 16%; p = 0.035). CONCLUSIONS In patients with DES-ISR, EES provided superior long-term clinical and angiographic results compared with DEB. (C) 2015 by the American College of Cardiology Foundation.

Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0735-1097, 1558-3597

JACC-Journal of the American College of Cardiology  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
23-33
PubMed:
26139054

Citas Recibidas en Web of Science: 292

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • angiography; percutaneous coronary intervention; proliferation; revascularization

Cita

Compartir