Early Healing Assessment with Optical Coherence Tomography of Everolimus-Eluting Stents with Bioabsorbable Polymer (Synergy (TM)) at 3 and 6 Months After Implantation
Autores de IDIVAL
Autores ajenos al IDIVAL
- Tejedor, P
- Duran, JM
- Monedero, J
- Laso, FS
- Calderon, MA
- Veiga, G
Unidades
Abstract
Objectives: In this study we sought to evaluate coverage and apposition of Synergy (TM) stent at 3 and 6 months after implantation. Background: The Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy (TM)) is a new generation drugeluting stent with features potentially favoring an early healing process which could make safe a shorter period of dual antiplatelet-therapy treatment. Methods: Prospective, two-centers study enrolling patients with similar lesions treated with Synergy (TM) stents undergoing examination with OCT at 3 and 6 months in the respective centers. Blinded analysis was done at a core lab. Co-primary endpoints were proportion of struts with coverage and with apposition at 3 and 6 months. Results: Finally, 22 patients (30 stents) in the 3 months group and 20 patients (30 stents) in the 6 months group were included. There were no significant differences between groups regarding clinical, angiographic measurements, and procedural data. The rate of strut coverage was 94.5% at 3 months and 96.6% at 6 months (P < 0.001), the rates of apposition were 93.8% and 96.2%, respectively, (P < 0.001), the proportion of uncovered but apposed struts was 2.5% and 1.9% (P = 0.03) and the proportion of uncovered and malapposed struts was 3% and 1.8%, respectively (P < 0.001). The maximal area of malapposition related with uncovered struts was 0.4360.4 mm(2) at 3 months and 0.14 +/- 0.2 mm(2) at 6 months (P = 0.001). Conclusions: The everolimus-eluting stent with absorbable polymer, Synergy (TM), is associated to a high degree of intimal coverage and apposition at 3 months after implantation with additional increase at 6 months. (C) 2015 Wiley Periodicals, Inc.
© 2015 Wiley Periodicals, Inc.
Datos de la publicación
- ISSN/ISSNe:
- 1522-1946, 1522-726X
- Tipo:
- Article
- Páginas:
- 67-73
- DOI:
- 10.1002/ccd.26299
- PubMed:
- 26526783
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS WILEY
Citas Recibidas en Web of Science: 31
Documentos
- No hay documentos
Filiaciones
Keywords
- coronary artery disease; drug-eluting stents; optical coherence tomography
Campos de Estudio
Cita
de la Torre JM, Tejedor P, Camarero TG, Duran JM, Lee DH, Monedero J, Laso FS, Calderon MA, Veiga G, Zueco J. Early Healing Assessment with Optical Coherence Tomography of Everolimus-Eluting Stents with Bioabsorbable Polymer (Synergy (TM)) at 3 and 6 Months After Implantation. Catheter. Cardiovasc. Interv. 2016. 88. (3):p. 67-73. IF:2,181. (3).
Actividad Investigadora