Cost-Effectiveness of Percutaneous Coronary Intervention with Cobalt-Chromium Everolimus Eluting Stents versus Bare Metal Stents: Results from a Patient Level Meta-Analysis of Randomized Trials

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Ferko, N
  • Ferrante, G
  • Hasegawa, JT
  • Schikorr, T
  • Soleas, IM
  • Hernandez, JB
  • Sabate, M
  • Kaiser, C
  • Brugaletta, S
  • Galatius, S
  • Cequier, A
  • Eberli, F
  • de Belder, A
  • Serruys, PW
  • Valgimigli, M

Unidades

Abstract

Background: Second-generation drug eluting stents (DES) may reduce costs and improve clinical outcomes compared to first-generation DES with improved cost-effectiveness when compared to bare metal stents (BMS). We aimed to conduct an economic evaluation of a cobalt-chromium everolimus eluting stent (Co-Cr EES) compared with BMS in percutaneous coronary intervention (PCI). Objective: To conduct a cost-effectiveness analysis (CEA) of a cobalt-chromium everolimus eluting stent (Co-Cr EES) versus BMS in PCI. Methods: A Markov state transition model with a 2-year time horizon was applied from a US Medicare setting with patients undergoing PCI with Co-Cr EES or BMS. Baseline characteristics, treatment effects, and safety measures were taken from a patient level meta-analysis of 5 RCTs (n=4,896). The base-case analysis evaluated stent-related outcomes; a secondary analysis considered the broader set of outcomes reported in the meta-analysis. esults: The base-case and secondary analyses reported an additional 0.018 and 0.013 quality-adjusted life years (QALYs) and cost savings of $236 and $288, respectively with Co-Cr EES versus BMS. Results were robust to sensitivity analyses and were most sensitive to the price of clopidogrel. In the probabilistic sensitivity analysis, Co-Cr EES was associated with a greater than 99% chance of being cost saving or cost effective (at a cost per QALY threshold of $50,000) versus BMS. onclusions: ing data from a recent patient level meta-analysis and contemporary cost data, this analysis found that PCI with Co-Cr EES is more effective and less costly than PCI with BMS. (c) 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

© 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

Datos de la publicación

ISSN/ISSNe:
1522-1946, 1522-726X

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS  WILEY

Tipo:
Article
Páginas:
994-1002
PubMed:
27527508

Citas Recibidas en Web of Science: 10

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • drug-eluting stent; bare metal stent; percutaneous coronary intervention; cost-effectiveness

Cita

Compartir