Usefulness of Drug-Eluting Balloons for Bare-Metal and Drug-Eluting In-Stent Restenosis (from the RIBS IV and V Randomized Trials)

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • José Javier Zueco Gil

    Autor

Autores ajenos al IDIVAL

  • Alfonso, F
  • Perez-Vizcayno, MJ
  • García Del Blanco B
  • Garcia-Touchard, A
  • Lopez-Minguez, JR
  • Sabate, M
  • Melgares, R
  • Hernandez, R
  • Moreno, R
  • Dominguez, A
  • Sanchis, J
  • Moris, C
  • Moreu, J
  • Cequier, A
  • Romaguera, R
  • Rivero, F
  • Cuesta, J
  • Gonzalo, N
  • Jimenez-Quevedo, P
  • Cardenas, A
  • Fernandez, C
  • Spanish Soc Cardiology

Unidades

Abstract

Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is particularly challenging. We sought to compare results of drug-eluting balloons in patients with DES-ISR with those in patients with bare-metal stent (BMS) ISR. A pooled analysis of the Restenosis Intra-Stent: Drug-Eluting Balloon versus Everolimus-Eluting Stent IV and V randomized trials was performed. Both trials had identical inclusion and exclusion criteria. Results of drug-eluting balloons in 95 patients with BMS-ISR and 154 patients with DES-ISR were compared. Patients with DES-ISR were more frequently diabetics, presented more often as an acute coronary syndrome and had more severe lesions and more frequently a focal pattern, including edge-ISR. Late angiographic findings (92% of eligible patients), including minimal lumen diameter (1.80 +/- 0.6 vs 2.01 +/- 0.6 mm, p = 0.001; absolute mean difference 0.21 mm; 95% confidence interval 0.04 to 0.38; p = 0.014) and restenosis rate (19% vs 9.5%, p <0.05) were poorer in DES-ISR. Results were consistent across 10 prespecified subgroups. Moreover, on multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR after adjusting for potential confounders (adjusted absolute mean difference 0.17 mm; 95% confidence interval 0.04 to 0.41; p = 0.019). Finally, at 1-year clinical follow-up (100% of patients), rates of target vessel revascularization (16% vs 6%, p = 0.02) and of the main combined clinical end point (18% vs 8%, p = 0.03) were significantly higher in patients treated for DES-ISR. In conclusion, this study confirms the efficacy of DEB for patients with ISR. However, the long-term clinical and angiographic results of DEB are poorer in patients with DES-ISR than in those with BMS-ISR. (ClinicalTrials.gov Identifier: NCT01239953 & NCT01239940). (C) 2017 Elsevier Inc. All rights reserved.

Copyright © 2017 Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0002-9149, 1879-1913

AMERICAN JOURNAL OF CARDIOLOGY  EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
983-990
PubMed:
28139220

Citas Recibidas en Web of Science: 10

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Cita

Compartir