Usefulness of Drug-Eluting Balloons for Bare-Metal and Drug-Eluting In-Stent Restenosis (from the RIBS IV and V Randomized Trials)
Autores de IDIVAL
Autores ajenos al IDIVAL
- Alfonso, F
- Perez-Vizcayno, MJ
- García Del Blanco B
- Garcia-Touchard, A
- Lopez-Minguez, JR
- Sabate, M
- Melgares, R
- Hernandez, R
- Moreno, R
- Dominguez, A
- Sanchis, J
- Moris, C
- Moreu, J
- Cequier, A
- Romaguera, R
- Rivero, F
- Cuesta, J
- Gonzalo, N
- Jimenez-Quevedo, P
- Cardenas, A
- Fernandez, C
- Spanish Soc Cardiology
Unidades
Abstract
Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is particularly challenging. We sought to compare results of drug-eluting balloons in patients with DES-ISR with those in patients with bare-metal stent (BMS) ISR. A pooled analysis of the Restenosis Intra-Stent: Drug-Eluting Balloon versus Everolimus-Eluting Stent IV and V randomized trials was performed. Both trials had identical inclusion and exclusion criteria. Results of drug-eluting balloons in 95 patients with BMS-ISR and 154 patients with DES-ISR were compared. Patients with DES-ISR were more frequently diabetics, presented more often as an acute coronary syndrome and had more severe lesions and more frequently a focal pattern, including edge-ISR. Late angiographic findings (92% of eligible patients), including minimal lumen diameter (1.80 +/- 0.6 vs 2.01 +/- 0.6 mm, p = 0.001; absolute mean difference 0.21 mm; 95% confidence interval 0.04 to 0.38; p = 0.014) and restenosis rate (19% vs 9.5%, p <0.05) were poorer in DES-ISR. Results were consistent across 10 prespecified subgroups. Moreover, on multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR after adjusting for potential confounders (adjusted absolute mean difference 0.17 mm; 95% confidence interval 0.04 to 0.41; p = 0.019). Finally, at 1-year clinical follow-up (100% of patients), rates of target vessel revascularization (16% vs 6%, p = 0.02) and of the main combined clinical end point (18% vs 8%, p = 0.03) were significantly higher in patients treated for DES-ISR. In conclusion, this study confirms the efficacy of DEB for patients with ISR. However, the long-term clinical and angiographic results of DEB are poorer in patients with DES-ISR than in those with BMS-ISR. (ClinicalTrials.gov Identifier: NCT01239953 & NCT01239940). (C) 2017 Elsevier Inc. All rights reserved.
Copyright © 2017 Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0002-9149, 1879-1913
- Tipo:
- Article
- Páginas:
- 983-990
- PubMed:
- 28139220
AMERICAN JOURNAL OF CARDIOLOGY EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 10
Documentos
- No hay documentos
Filiaciones
Campos de Estudio
Cita
Alfonso F, Perez MJ, García Del Blanco B, Garcia A, Lopez JR, Sabate M, Zueco J, Melgares R, Hernandez R, Moreno R, Dominguez A, Sanchis J, Moris C, Moreu J, Cequier A, Romaguera R, Rivero F, Cuesta J, Gonzalo N, Jimenez P, Cardenas A, Fernandez C, Spanish C. Usefulness of Drug-Eluting Balloons for Bare-Metal and Drug-Eluting In-Stent Restenosis (from the RIBS IV and V Randomized Trials). Am. J. Cardiol. 2017. 119. (7):p. 983-990. IF:3,398. (2).