The long interaction pathlengths provided by hollow-core photonic bandgap fibers (HC-PBFs) are especially advantageous for the detection of weakly absorbing gases such as methane (CH(4)). In this paper, we demonstrate methane sensing with a 1670-nm band HC-PBF. A multiline algorithm is used to fit the R(6) manifold (near 1645 nm) and, in this way, to measure the gas concentration. With this method, a minimum detectivity of 10 ppmv for the system configuration was estimated.
Datos de la publicación
- ISSN/ISSNe:
- 1094-4087, 1094-4087
- Tipo:
- Article
- Páginas:
- 17570-17576
- DOI:
- 10.1364/OE.15.017570
- PubMed:
- 19551051
OPTICS EXPRESS Optica Publishing Group
Citas Recibidas en Web of Science: 98
Documentos
- No hay documentos
Filiaciones
Campos de Estudio
Cita
Cubillas AM, Silva M, Lazaro JM, Conde OM, Petrovich MN, Lopez JM. Methane detection at 1670-nm band using a hollow-core photonic bandgap fiber and a multiline algorithm. Opt. Express. 2007. 15. (26):p. 17570-17576. IF:4,009. (1).