Efficacy and safety of endotracheal intubation performed in moving vs motionless environments
Fecha de publicación:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Castejón de la Encina MªE
- Sanjuán Quiles Á
- García Aracil N
- José Alcaide L
- Richart Martínez M
Abstract
Objective. To compare the efficacy and safety of endotracheal intubation (ETI) in a simulated clinical environment in motion vs a motionless one. Method. Clinical simulation trial of ET! with 3 endotracheal tubes (Airtraq, Fast-trach, Macintosh laryngoscope) in mannequins with realistic physiological responses (MetiMan) in 2 scenarios: an environment in motion vs a motionless one. Thirty-six physicians expert in prehospital ETI participated. Outcome variables were successful intubation, effective intubation, number of attempts, maximum apnea time, and total maneuver time. The safety variables were the presence of bradycardia, tachycardia, or high or low systolic blood pressures (ie, 20% variation from baseline); hypoxemia (decrease in oxygen saturation to <90% or 10% below baseline), tube placement in the esophagus or main bronchus, and dental trauma. Results. No statistically significant differences between the 2 scenarios were found in the numbers of successful ET] (motionless, 71 [65.7%]; in motion, 67 [62.0%]; P=.277) or effective ETI (motionless, 104 [96.3%]; in motion, 105 [97.2%]; P=.108). Likewise, the number of attempts were similar (motionless, 91 [84.2%]; in motion, 90 [83.3%]; P=.305). Nor did we see differences in the mean (SD) maximum apnea times (motionless, 14.0 [5.6] seconds; in motion, 14.9 [8.1] seconds; P=.570) or mean total maneuver times (motionless, 236.7 [73.4] seconds; in motion, 210.3 [77.9] seconds; P=.164). The prevalences of bradycardia, tachycardia, high or low systolic blood pressure, hypoxemia, placements in the esophagus or bronchus, and dental trauma also did not differ significantly between the 2 scenarios. Conclusion. Neither efficacy nor safety variables differed significantly when ET! was performed in mannequins in a motionless environment vs one simulating ambulances in motion.
Datos de la publicación
- ISSN/ISSNe:
- 1137-6821, 2386-5857
- Tipo:
- Article
- Páginas:
- 5-10
- PubMed:
- 28825262
Emergencias Soc Espanola Medicina Urgencias & Emergencias-SEMES
Citas Recibidas en Web of Science: 4
Documentos
- No hay documentos
Métricas
Filiaciones
Keywords
- Endotracheal intubation; Ambulance in motion; Medical devices; Prehospital emergencies
Campos de Estudio
Cita
Castejón de la Encina M, Sanjuán Á, Del Moral Vicente I, García N, José L, Richart M. Efficacy and safety of endotracheal intubation performed in moving vs motionless environments. Emergencias. 2017. 29. (1):p. 5-10. IF:3,028. (1).
Actividad Investigadora