Normal Values of Magnetic Relaxation Parameters of Spine Components with the Synthetic MRI Sequence

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • Marta Drake Pérez

    Autor

Autores ajenos al IDIVAL

  • Delattre BMA
  • Boto, J
  • Fitsiori, A
  • Lovblad, KO
  • Boudabbous, S
  • Vargas, MI

Unidades

Abstract

BACKGROUND AND PURPOSE: SyMRI is a technique developed to perform quantitative MR imaging. Our aim was to analyze its potential use for measuring relaxation times of normal components of the spine and to compare them with values found in the literature using relaxometry and other techniques. MATERIALS AND METHODS: Thirty-two spine MR imaging studies (10 cervical, 5 dorsal, 17 lumbosacral) were included. A modified multiple-dynamic multiple-echo sequence was added and processed to obtain quantitative T1 (millisecond), T2 (millisecond), and proton density (percentage units [pu]) maps for each patient. An ROI was placed on representative areas for CSF, spinal cord, intervertebral discs, and vertebral bodies, to measure their relaxation. RESULTS: Relaxation time means are reported for CSF (T1 = 4273.4 ms; T2 = 1577.6 ms; proton density = 107.5 pu), spinal cord (T1 = 780.2 ms; T2 = 101.6 ms; proton density = 58.7 pu), normal disc (T1 = 1164.9 ms; T2 = 101.9 ms; proton density = 78.9 pu), intermediately hydrated disc (T1 = 723 ms; T2 = 66.8 ms; proton density = 60.8 pu), desiccated disc (T1 = 554.4 ms; T2 = 55.6 ms; proton density = 47.6 ms), and vertebral body (T1 = 515.3 ms; T2 = 100.8 ms; proton density = 91.1 pu). Comparisons among the mean T1, T2, and proton density values showed significant differences between different spinal levels (cervical, dorsal, lumbar, and sacral) for CSF (proton density), spinal cord (T2 and proton density), normal disc (T1, T2, and proton density), and vertebral bodies (T1 and proton density). Significant differences were found among mean T1, T2, and proton density values of normal, intermediately hydrated, and desiccated discs. CONCLUSIONS: Measurements can be easily obtained on SyMRI and correlated with previously published values obtained using conventional relaxometry techniques.

© 2018 by American Journal of Neuroradiology.

Datos de la publicación

ISSN/ISSNe:
0195-6108, 1936-959X

AMERICAN JOURNAL OF NEURORADIOLOGY  AMER SOC NEURORADIOLOGY

Tipo:
Article
Páginas:
788-795
PubMed:
29496723

Citas Recibidas en Web of Science: 32

Métricas

Filiaciones mostrar / ocultar

Campos de Estudio

Cita

Compartir