Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients With New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement The MARE Study

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Rodes-Cabau, J
  • Urena, M
  • Nombela-Franco, L
  • Amat-Santos, I
  • Kleiman, N
  • Munoz-Garcia, A
  • Atienza, F
  • Serra, V
  • Deyell, MW
  • Veiga-Fernandez, G
  • Masson, JB
  • Canadas-Godoy, V
  • Himbert, D
  • Castrodeza, J
  • Elizaga, J
  • Francisco Pascual J
  • Webb, JG
  • Asmarats, L
  • Pelletier-Beaumont, E
  • Philippon, F

Unidades

Abstract

OBJECTIVES The authors sought to determine: 1) the global arrhythmic burden; 2) the rate of arrhythmias leading to a treatment change; and 3) the incidence of high-degree atrioventricular block (HAVB) at 12-month follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). BACKGROUND Controversial data exist on the occurrence of significant arrhythmias in patients with LBBB post-TAVR. METHODS This was a multicenter prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR with the balloon-expandable SAPIEN XT/3 valve (n = 53), or the self-expanding CoreValve/Evolut R system (n = 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted at 4 (3 to 6) days post-TAVR, and patients had continuous electrocardiogram monitoring for 12 months. All arrhythmic events were adjudicated in a central electrocardiography core lab. Primary endpoints were the incidence of arrhythmias leading to a treatment change, and the incidence of HAVB at 12-month follow-up. RESULTS A total of 1,553 new arrhythmic events were detected in 44 patients (1,443 episodes of tachyarrhythmia in 26 patients [atrial fibrillation/flutter/atrial tachycardia: 1,427, ventricular tachycardia 16]; 110 episodes of bradyarrhythmia in 21 patients [HAVB 54, severe bradycardia 56]). All arrhythmic events were silent in 34 patients (77%), the arrhythmic event led to a treatment change in 19 patients (18%), and 11 patients (11%) required pacemaker or implantable cardioverter-defibrillator implantation (due to HAVB, severe bradycardia, or ventricular tachycardia episodes in 9, 1, and 1 patient, respectively). A total of 12 patients died at 1-year follow-up, 1 from sudden death. CONCLUSIONS A high incidence of arrhythmic events was observed at 1-year follow-up in close to one-half of the patients with LBBB post-TAVR. Significant bradyarrhythmias occurred in one-fifth of the patients, and PPM was required in nearly one-half of them. These data support the use of a cardiac monitoring device for close follow-up and expediting the initiation of treatment in this challenging group of patients. (Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block in Patients With New-onset PeRsistent LEft Bundle Branch Block After Transcatheter Aortic Valve Implantation [MARE study]: NCT02153307) (C) 2018 by the American College of Cardiology Foundation.

Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
1936-8798, 1876-7605

JACC-CARDIOVASCULAR INTERVENTIONS  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1495-1505
PubMed:
30031719

Citas Recibidas en Web of Science: 134

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • atrial fibrillation; bradyarrhythmias; left bundle branch block; pacemaker implantation; transcatheter aortic valve replacement

Cita

Compartir