EUS-guided tissue acquisition in the study of the adrenal glands: Results of a nationwide multicenter study

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Martin-Cardona A
  • Fernandez-Esparrach G
  • Subtil JC
  • Iglesias-Garcia J
  • Garcia-Guix M
  • Barturen Barroso A
  • Gimeno-Garcia AZ
  • Esteban JM
  • Pardo Balteiro A
  • Velasco-Guardado A
  • Vazquez-Sequeiros E
  • Loras C
  • Martinez-Moreno B
  • Castellot A
  • Huertas C
  • Martinez-Lapiedra M
  • Sanchez-Yague A
  • Morales-Alvarado VJ
  • Betes M
  • de la Iglesia D
  • Sánchez-Montes C
  • Lozano MD
  • Lariño-Noia J
  • Gines A
  • Tebe C
  • Gornals JB
  • On belhaf of Spanish Group for EUS-Guided TA in the adrenal gland

Unidades

Abstract

Background There are limited data about the role of endoscopic ultrasound-guided tissue acquisition (EUS-TA), by fine needle aspiration (EUS-FNA) or biopsy (EUS-FNB), in the evaluation of the adrenal glands (AG). The primary aim was to assess the diagnostic yield and safety. The secondary aims were the malignancy predictors, and to create a predictive model of malignancy. Methods This was a retrospective nationwide study involving all Spanish hospitals experienced in EUS-TA of AGs. Inclusion period was from April-2003 to April-2016. Inclusion criteria: all consecutive cases that underwent EUS-TA of AGs. EUS and cytopathology findings were evaluated. Statistical analyses: diagnostic accuracy of echoendoscopist's suspicion using cytology by EUS-TA, as gold standard; multivariate logistic regression model to predict tumor malignancy. Results A total of 204 EUS-TA of AGs were evaluated. Primary tumor locations were lung70%, others19%, and unknown 11% AG samples were adequate for cytological diagnosis in 91%, and confirmed malignancy in 60%. Diagnostic accuracy of the endosonographer's suspicion was 68%. The most common technique was: a 22-G (65%) and cytological needle (75%) with suction -syringe (66%). No serious adverse events were described. The variables most associated with malignancy were size>30mm (OR2.27; 95%Cl, 1.16-4.05), heterogeneous echo pattern (OR2.11; 95%Cl, 1.1-3.9), variegated AG shape (OR2.46; 95%Cl, 1-6.24), and endosonographer suspicion (OR17.46; 95%Cl, 6.2-58.5). The best variables for a predictive multivariate logistic model of malignancy were age, sex, echo-pattern, and AG-shape. Conclusions EUS-TA of the AGs is a safe, minimally invasive procedure, allowing an excellent diagnostic yield. These results suggest the possibility of developing a pre-EUS procedure predictive malignancy model.

Datos de la publicación

ISSN/ISSNe:
1932-6203, 1932-6203

PLoS One  PUBLIC LIBRARY SCIENCE

Tipo:
Article
Páginas:
-
PubMed:
31170163

Citas Recibidas en Web of Science: 17

Documentos

Métricas

Filiaciones mostrar / ocultar

Campos de Estudio

Cita

Compartir