Comparison of One-Year Outcomes Between the ihtDEStiny BD Stent and the Durable-Polymer Everolimus- and Zotarolimus-Eluting Stents: A Propensity-Score-Matched Analysis

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Ocaranza Sanchez R
  • Santas Alvarez M
  • Pinar Bermudez E
  • Hurtado Martinez JA
  • Garcia Del Blanco B
  • Otaegui I
  • Fernandez Nofrerias E
  • Carrillo Suarez X
  • Casanova Sandoval JM
  • Rivera Aguilar PK
  • Cid B
  • Trillo R
  • Lozano Ruiz-Poveda F
  • Peral Disdier V
  • Telleria M
  • Torres A
  • Sanchis J
  • Oliva X
  • Freixa X
  • Sadaba Sagredo M
  • Moreu J
  • Hernández F

Unidades

Abstract

Objectives: We sought to evaluate clinical outcomes in patients treated with the drug-eluting stent ihtDEStiny BD. Background: The ihtDEStiny BD stent is a metallic sirolimus eluting stent with a biodegradable polymer with both drug and polymer coating the abluminal surface of the stent and balloon. Methods: In this study, the clinical outcomes of a multicenter prospective registry of patients treated with this stent (DEStiny group) were analyzed and compared with those of a control group of patients treated with durable polymer everolimus or zotarolimus eluting stents (CONTROL group) paired by propensity score matching. Primary outcome was the target vessel failure (TVF) at 12 months defined as a composite of cardiac death, target vessel myocardial infarction (TV-MI) and target vessel revascularization (TVR). Results: A total of 350 patients were included in the DESTtiny group. The control group consisted initially of 1368 patients, but aftermatching (1:1) 350 patients were selected as CONTROL group. The baseline clinical, angiographic and procedural characteristics were quite comparable in both groups. At 12 months follow up the TVF was 6.6% in DEStiny group and 6.3% in CONTROL group (p=0.8). No differences were observed for any of the individual components of the primary endpoint: cardiac death 1.1% vs. 1.4%, TV-MI 3.4% vs. 3.7% and TVR 2.6% vs. 2.3% respectively. Conclusions: The use of ihtDEStiny stent in real practice is associated with a clinical performance at 12 months follow up that appears to be non-inferior to the most widely used and largely evidence supported durable polymer drug eluting stents. A longer follow up is warranted. (C) 2020 Elsevier Inc. All rights reserved.

Copyright © 2020 Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
1553-8389, 1878-0938

Cardiovascular Revascularization Medicine  ELSEVIER INC

Tipo:
Article
Páginas:
1-6
PubMed:
33060037
Enlace a otro recurso:
www.sciencedirect.com

Citas Recibidas en Web of Science: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Coronary artery disease; Drug-eluting stent; Target vessel failure

Cita

Compartir