First-in-man randomised comparison of the Angiolite durable fluoroacrylate polymer-based sirolimus-eluting stent versus a durable fluoropolymer-based everolimus-eluting stent in patiens with coronary artery disease: the ANGIOLITE trial
Autores de IDIVAL
Autores ajenos al IDIVAL
- Moreu, J
- Moreno-Gomez, R
- de Prado, AP
- del Blanco, BG
- Trillo, R
- Pinar, E
- Molina, E
- Merchan, A
- Diaz-Fernandez, JF
- Amat, I
Unidades
Abstract
Aims: The durable fluoroacrylate polymer-based sirolimus-eluting stent (Angiolite SES) has shown promising preclinical and clinical results regarding inflammatory vascular reaction and neointimal healing. We aimed to compare performance between the Angiolite SES and an everolimus-eluting stent (EES) in patients with coronary artery disease. Methods and results: The ANGIOLITE trial, a prospective, randomised, multicentre trial, compared the restenosis parameters of both stents in de novo coronary lesions. The primary endpoint was late lumen loss at six-month angiographic follow-up. In-stein healing was assessed by optical coherence tomography (OCT). The main clinical endpoint was target lesion failure (TLF) evaluated up to 24 months. A total of 223 patients were randomised 1:1 to EES or SES. At six months, in-stent late lumen loss was 0.08 mm (+/- 0.38) for EES vs 0.04 mm (+/- 0.39) for SES (difference=-0.04 mm, 95% CI: -0.15, 0.07, p for noninferiority=0.002). By OCT, the rate of uncovered to total number of struts score >30% was comparable between the groups whereas neointimal thickness was reduced in the SES arm (9.0% [7.6, 10.6] vs 9.9% [8.5, 11.3], p=0.41; and 86.4 [81.6, 91.2] mu m vs 72.1 [68.2, 76.0] mu m, p<0.01, respectively). At 24 months, TLF occurred in eight patients (7.6% [3.3, 14.5]) in the EES aim and in seven patients (7.1% [2.9, 14.0]) in the SES arm (p=0.88). The del mite/probable stent thrombosis rate was comparable between the groups (1.9% [0.2, 6.7] vs 1.0% [0.0, 5.5] EES vs SES, respectively; p=0.59). Conclusions: This trial demonstrates similar antirestenotic efficacy at midterm follow-up of the Angiolite SES vs an EES. Clinical endpoints were comparable between the groups at two-year follow-up.
Datos de la publicación
- ISSN/ISSNe:
- 1774-024X, 1969-6213
- Tipo:
- Article
- Páginas:
- 1081-104
- PubMed:
- 31310239
EuroIntervention EUROPA EDITION
Citas Recibidas en Web of Science: 10
Documentos
- No hay documentos
Filiaciones
Campos de Estudio
Cita
Moreu J, Moreno R, de Prado AP, del Blanco BG, Trillo R, Pinar E, Molina E, Zueco J, Merchan A, Diaz JF, Amat I. First-in-man randomised comparison of the Angiolite durable fluoroacrylate polymer-based sirolimus-eluting stent versus a durable fluoropolymer-based everolimus-eluting stent in patiens with coronary artery disease: the ANGIOLITE trial. EuroIntervention. 2019. 15. (12):p. 1081-104. IF:4,018. (2).
Actividad Investigadora