Impact of operators experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry2
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Cruz-González I
- Torres Saura F
- Trejo-Velasco B
- Antonio Fernández Díaz J
- Fajardo Molina R
- Del Valle-Fernández R
- Moreno Terribas G
- Martí Sánchez D
- López-Mínguez JR
- Gomez-Blazquez I
- Sanmartin Pena JC
- Botas J
- Martin Lorenzo P
- Palazuelos J
- Albarrán Rincon R
- Mohandes M
- Martí G
- Valero E
- Gutiérrez H
- Amat-Santos IJ
- Nombela-Franco L
- Salinas P
- Teruel L
- Gomez-Hospital JA
- Arzamendi D
- Torres Sanabria M
- Calle Pérez G
- Cañadas Pruaño D
- Pérez de Prado A
- Benito González T
- Arroyo-Úcar E
- Estévez-Loureiro R
- Caneiro-Queija B
- Ibañez Criado JL
- Ruiz-Nodar JM
Unidades
Abstract
Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, "real-world" registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed <= 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA(2)DS(2)-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the center's previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operator's experience with its previous device iteration or the number of Watchman FLX devices implanted.
© 2021 Published by Elsevier B.V.
Datos de la publicación
- ISSN/ISSNe:
- 2352-9067, 2352-9067
- Tipo:
- Article
- Páginas:
- 100941-100941
- PubMed:
- 35024431
IJC Heart & Vasculature ELSEVIER IRELAND LTD
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- Atrial fibrillation; Devices; ICE, intracardiac echocardiography; LAA, left atrial appendage; LAAO, left atrial appendage occlusion; Left atrial appendage occlusion; OAC, oral anticoagulation; Outcomes; TEE, transesophageal echocardiography
Cita
Cruz I, Torres F, Trejo B, Antonio Fernández Díaz J, Fajardo R, Del Valle R, Moreno G, Martí D, López JR, Gomez I, Sanmartin JC, Botas J, Martin P, Palazuelos J, Albarrán R, Mohandes M, Rodriguez FJ, Martí G, Valero E, Gutiérrez H, Amat IJ, Nombela L, Salinas P, Teruel L, Gomez JA, Arzamendi D, Torres M, Calle G, Cañadas D, Pérez de Prado A, Benito T, Arroyo E, Estévez R, Caneiro B, Ibañez JL, Ruiz JM. Impact of operators experience on <i>peri</i>-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry<SUP>2</SUP>. IJC Heart Vasc. 2022. 38. p. 100941-100941.
Actividad Investigadora