Impact of operators experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry2

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Cruz-González I
  • Torres Saura F
  • Trejo-Velasco B
  • Antonio Fernández Díaz J
  • Fajardo Molina R
  • Del Valle-Fernández R
  • Moreno Terribas G
  • Martí Sánchez D
  • López-Mínguez JR
  • Gomez-Blazquez I
  • Sanmartin Pena JC
  • Botas J
  • Martin Lorenzo P
  • Palazuelos J
  • Albarrán Rincon R
  • Mohandes M
  • Martí G
  • Valero E
  • Gutiérrez H
  • Amat-Santos IJ
  • Nombela-Franco L
  • Salinas P
  • Teruel L
  • Gomez-Hospital JA
  • Arzamendi D
  • Torres Sanabria M
  • Calle Pérez G
  • Cañadas Pruaño D
  • Pérez de Prado A
  • Benito González T
  • Arroyo-Úcar E
  • Estévez-Loureiro R
  • Caneiro-Queija B
  • Ibañez Criado JL
  • Ruiz-Nodar JM

Unidades

Abstract

Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, "real-world" registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed <= 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA(2)DS(2)-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the center's previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operator's experience with its previous device iteration or the number of Watchman FLX devices implanted.

© 2021 Published by Elsevier B.V.

Datos de la publicación

ISSN/ISSNe:
2352-9067, 2352-9067

IJC Heart & Vasculature  ELSEVIER IRELAND LTD

Tipo:
Article
Páginas:
100941-100941
PubMed:
35024431

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Atrial fibrillation; Devices; ICE, intracardiac echocardiography; LAA, left atrial appendage; LAAO, left atrial appendage occlusion; Left atrial appendage occlusion; OAC, oral anticoagulation; Outcomes; TEE, transesophageal echocardiography

Cita

Compartir