Clinical Predictors for Procedural Stroke and Implications for Embolic Protection Devices during TAVR: Results from the Multicenter Transcatheter Aortic Valve Replacement In-Hospital Stroke (TASK) Study

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Berkovitch, Anat
  • Segev, Amit
  • Maor, Elad
  • Sedaghat, Alexander
  • Finkelstein, Ariel
  • Saccocci, Matteo
  • Kornowski, Ran
  • Latib, Azeem
  • Sondergaard, Lars
  • Mylotte, Darren
  • Van Royen, Niels
  • Zaman, Azfar G.
  • Robert, Pierre
  • Sinning, Jan-Malte
  • Steinvil, Arie
  • Maisano, Francesco
  • Orvin, Katia
  • Iannopollo, Gianmarco
  • Lee, Dae-Hyun
  • De Backer, Ole
  • Mercanti, Federico
  • van der Wulp, Kees
  • Shome, Joy
  • Tchetche, Didier
  • Barbash, Israel M.

Unidades

Abstract

Background: Data to support the routine use of embolic protection devices for stroke prevention during transcatheter aortic valve replacement (TAVR) are controversial. Identifying patients at high risk for peri-procedural cerebrovascular events may facilitate effective patient selection for embolic protection devices during TAVR. Aim: To generate a risk score model for stratifying TAVR patients according to peri-procedural cerebrovascular events risk. Methods and results: A total of 8779 TAVR patients from 12 centers worldwide were included. Peri-procedural cerebrovascular events were defined as an ischemic stroke or a transient ischemic attack occurring <= 24 h from TAVR. The peri-procedural cerebrovascular events rate was 1.4% (n = 127), which was independently associated with 1-year mortality (hazards ratio (HR) 1.78, 95% confidence interval (CI) 1.06-2.98, p < 0.028). The TASK risk score parameters were history of stroke, use of a non-balloon expandable valve, chronic kidney disease, and peripheral vascular disease, and each parameter was assigned one point. Each one-point increment was associated with a significant increase in peri-procedural cerebrovascular events risk (OR 1.96, 95% CI 1.56-2.45, p < 0.001). The TASK score was dichotomized into very-low, low, intermediate, and high (0, 1, 2, 3-4 points, respectively). The high-risk TASK score group (OR 5.4, 95% CI 2.06-14.16, p = 0.001) was associated with a significantly higher risk of peri-procedural cerebrovascular events compared with the low TASK score group. Conclusions: The proposed novel TASK risk score may assist in the pre-procedural risk stratification of TAVR patients for peri-procedural cerebrovascular events.

Datos de la publicación

ISSN/ISSNe:
2075-4426, 2075-4426

Journal of Personalized Medicine  MDPI

Tipo:
Article
Páginas:
-
PubMed:
35887554

Citas Recibidas en Web of Science: 4

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • aortic stenosis; stroke; transcatheter aortic valve replacement

Campos de Estudio

Cita

Compartir