Sirolimus-coated balloon versus everolimus-eluting stent in de novo coronary artery disease: Rationale and design of the TRANSFORM II randomized clinical trial

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Greco A
  • Sciahbasi A
  • Abizaid A
  • Mehran R
  • Rigattieri S
  • Alfonso F
  • Cortese B

Unidades

Abstract

Background Percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation is a widely adopted strategy for the treatment of de novo coronary artery disease. DES implantation conveys an inherent risk for short- and long-term complications, including in-stent restenosis and stent thrombosis. Drug-coated balloons are emerging as an alternative approach to fulfill the "leaving nothing behind" principle and avoid long-term DES-related complications. Design TRANSFORM II is an investigator-initiated, multicenter, noninferiority, randomized clinical trial, testing a sirolimus-coated balloon (SCB) versus the standard of care for native coronary vessels with a 2-3 mm diameter, in terms of 12-month target lesion failure (TLF; primary endpoint) and net adverse cardiovascular events (coprimary endpoint). Patients undergoing PCI will be randomized to be treated with either SCB or new-generation everolimus-eluting stent and will be followed up clinically for up to 60 months. Assuming a TLF rate of 8% at 12 months with DES, a sample size of 1325 patients was chosen to ensure an 80% power to detect a 1.5% lower incidence in the SCB group with a type I error rate of 0.05. The TRANSFORM II trial is registered on (identification number NCT04893291). Several substudies, including an optical coherence tomography assessment at 9 months (intracoronary imaging substudy), will investigate the study device in different clinical and lesion settings. Conclusions The randomized TRANSFORM II trial will determine whether a novel SCB is noninferior to a current everolimus-eluting stent when adopted for the treatment of de novo lesions in coronary vessels with a diameter between 2 and 3 mm.

© 2022 Wiley Periodicals LLC.

Datos de la publicación

ISSN/ISSNe:
1522-1946, 1522-726X

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS  WILEY

Tipo:
Article
Páginas:
544-552
PubMed:
36054266

Citas Recibidas en Web of Science: 55

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • coronary artery disease; drug-coated balloon; drug-eluting stent; percutaneous coronary intervention; randomized clinical trial; study design

Cita

Compartir