Hemodiálisis extendida frente a convencional o hemodiafiltración en línea. Estudio comparativo de necesidad de heparina y coagulación del sistema

Fecha de publicación:

Autores de IDIVAL

  • Raquel Pelayo Alonso

    Autor

  • José Luis Cobo Sánchez

    Autor

  • Patricia Martínez Álvarez

    Autor

  • Marta Portilla Sanchez

    Autor

Autores ajenos al IDIVAL

  • Ibarguren-Rodríguez E

Abstract

Abstract Introduction: The recent emergence of medium-cut membranes offers an alternative for the removal of medium-sized molecules and new dialytic therapy, expanded hemodialysis. These membranes are characterised by a larger pore size that could affect the removal of heparin used during hemodialysis sessions. Objective: To determine whether there are differences in the need for heparin and the coagulation status of the system and dialyser according to dialysis technique. Material and Method: Quasi-experimental study in hemodialysis patients with two study periods, in the first, the patient received conventional hemodialysis or hemodiafiltration and in the second, expanded hemodialysis with medium-cut membranes. Results: The dialyser was partially clotted in 10.3% of expanded hemodialysis sessions compared to 19.1% of conventional hemodialysis sessions and 11.4% of haemodiafiltration sessions (p=0.011). Conclusions: Expanded hemodialysis offers better final coagulation status of the system and dialyser than other membranes.

Datos de la publicación

ISSN/ISSNe:
2254-2884, 2255-3517

Enfermería Nefrológica  Sociedad Española de Enfermería Nefrológica

Tipo:
Article
Páginas:
272-277