Background: The current incidence and outcomes of structural transcatheter procedures in heart transplant (HTx) recipients and left-ventricular assist devices (LVAD) carriers is unknown. Aims: To provide insights on structural transcatheter procedures performed across HTx and LVAD patients in Spain. Methods: Multicenter, ambispective, observational nationwide registry. Results: Until May/2023, 36 percutaneous structural interventions were performed (78% for HTx and 22% for LVAD) widely varying among centers (0%-1.4% and 0%-25%, respectively). Percutaneous mitral transcatheter edge-to-edge (TEER) was the most common (n = 12, 33.3%), followed by trancatheter aortic valve replacement (n = 11, 30.5%), and tricuspid procedures (n = 9, 25%). Mitral TEER resulted in mild residual mitral regurgitation in all but one case, mean gradient was <5 mmHg in 75% of them at 1-year, with no mortality and 8.3% re-admission rate. Tricuspid TEER resulted in 100% none/ mild residual regurgitation with a 1-year mortality and readmission rates of 22% and 28.5%, respectively. Finally, trancatheter aortic valve replacement procedures (n = 8 in LVADs due to aortic regurgitation and n = 3 in HTx), were successful in all cases with one prosthesis degeneration leading to severe aortic regurgitation at 1year, 18.2% mortality rate and no re-admissions. Globally, major bleeding rates were 7.9% and 12.5%, thromboembolic events 3.7% and 12.5%, readmissions 37% and 25%, and mortality 22% and 25%, in HTx and LVADs respectively. No death was related to the implanted transcatheter device. Conclusions: Most centers with HTx/LVAD programs perform structural percutaneous procedures but with very inconsistent incidence. They were associated with good safety and efficacy, but larger studies are required to provide formal recommendations.

Datos de la publicación

ISSN/ISSNe:
0167-5273, 1874-1754

International Journal of Cardiology  ELSEVIER IRELAND LTD

Tipo:
Article
Páginas:
132340-132340
PubMed:
38992809

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Heart transplant; LVAD; Percutaneous therapies. TAVI. TEER. CAVI.; LAAO

Cita

Compartir