PoLambRimetry: a multispectral polarimetric atlas of lamb brain

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • Verónica Mieites Alonso

    Autor

  • Olga María Conde Portilla

    Autor

Autores ajenos al IDIVAL

  • Anichini, Giulio
  • Qi, Ji
  • O'Neill, Kevin
  • Elson, Daniel S

Unidades

Abstract

Significance Mueller matrix imaging (MMI) is a comprehensive form of polarization imaging useful for assessing structural changes. However, there is limited literature on the polarimetric properties of brain specimens, especially with multispectral analysis. Aim We aim to employ multispectral MMI for an exhaustive polarimetric analysis of brain structures, providing a reference dataset for future studies and enhancing the understanding of brain anatomy for clinicians and researchers. Approach A multispectral wide-field MMI system was used to measure six fresh lamb brain specimens. Multiple decomposition methods (forward polar, symmetric, and differential) and polarization invariants (indices of polarimetric purity and anisotropy coefficients) have been calculated to obtain a complete polarimetric description of the samples. A total of 16 labels based on major brain structures, including grey matter (GM) and white matter (WM), were identified. K-nearest neighbors classification was used to distinguish between GM and WM and validate the feasibility of MMI for WM identification. Results As the wavelength increases, both depolarization and retardance increase, suggesting enhanced tissue penetration into deeper layers. Moreover, utilizing multiple wavelengths allowed us to track dynamic shifts in the optical axis of retardance within the brain tissue, providing insights into morphological changes in WM beneath the cortical surface. The use of multispectral data for classification outperformed all results obtained with single-wavelength data and provided over 95% accuracy for the test dataset. Conclusions The consistency of these observations highlights the potential of multispectral wide-field MMI as a non-invasive and effective technique for investigating the brain's architecture.

Datos de la publicación

ISSN/ISSNe:
1083-3668, 1560-2281

JOURNAL OF BIOMEDICAL OPTICS  SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS

Tipo:
Article
Páginas:
96002-96002
PubMed:
39290462

Citas Recibidas en Web of Science: 5

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Mueller matrix imaging; multispectral imaging; wide field; non-invasive imaging; brain tissue; optical properties

Campos de Estudio

Cita

Compartir