Incidence and Impact of Structural Valve Deterioration Following TAVI: a Multicenter Real-World Study.

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Silva I
  • Alperi A
  • Muñoz A
  • Cheema A
  • Nombela L
  • Tay E
  • Urena M
  • Asmarats L
  • Del Trigo M
  • Lim Y
  • Gutierrez Alonso L
  • Regueiro A
  • Campelo-Parada F
  • Serra V
  • Del Val D
  • Barbosa Ribeiro H
  • Ternacle J
  • Vilalta V
  • Vidal P
  • Belahnech Y
  • Alfonso F
  • Nuche J
  • Rodes-Cabau J
  • Pibarot P

Unidades

Abstract

AIMS: Valve durability becomes a major issue as transcatheter aortic valve implantation (TAVI) is expanding to populations with longer life expectancy. We sought to i) determine the incidence of structural valve deterioration (SVD), ii) compare the incidence of SVD between balloon-expandable (BE) and self-expandable (SE) valves, and iii) analyze the impact of SVD. METHODS AND RESULTS: 2040 patients who underwent TAVI (2007-2020) from 9 centers were included. After inverse probability treatment weighting (IPTW), 1848 patients were selected (973 BE and 875 SE). SVD was defined using recent echocardiographic definitions according to VARC-3 criteria: Median follow-up was 4.2 (IQR: 2.5-5.7) years. The estimated incidence of SVD and bioprosthetic valve failure (BVF) at 8-years follow-up for the overall cohort were 13.3% (95%CI 9.8-18%) and 11.5% (95%CI 8.9-14.8%), respectively. After IPTW and a median follow-up of 4 years, the risk of SVD (5.25 % vs. 1.19%; HR 10.25, 95%CI 3.79-27.71, p <0.001), and all-cause BVF (6.41% vs. 3.2%; HR 2.1, 95%CI 1.27-3.47 p=0.004), was significantly higher for BE compared to SE recipients. Patients developing SVD had a trend towards a higher incidence of cardiovascular death (p=0.06), as well as a significantly higher risk of heart failure rehospitalization (p=0.048). After IPTW, there were no differences between BE and SE recipients in the combined endpoint of cardiovascular death, heart failure rehospitalization and valve reintervention (p=0.46). CONCLUSIONS: In this real-world registry, the incidence of SVD at 8-years after TAVI was relatively low. The risk of SVD was higher among BE compared to SE valve recipients. SVD was associated with increased risk of heart failure rehospitalization and a trend towards a higher risk of cardiovascular death.

© The Author(s) 2025. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.

Datos de la publicación

ISSN/ISSNe:
2047-2404, 2047-2412

European Heart Journal-Cardiovascular Imaging  OXFORD UNIV PRESS

Tipo:
Article
Páginas:
1018-1028
PubMed:
40059432

Citas Recibidas en Web of Science: 7

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aortic stenosis; transcatheter aortic valve replacement; valve deterioration

Campos de Estudio

Cita

Compartir