Balloon-Expandable versus Self-Expanding Valves in Patients With Prior Surgical Mitral Valve Replacement Undergoing Transcatheter Aortic Valve Replacement.

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Asmarats L
  • Jiménez-Quevedo P
  • Amat-Santos IJ
  • Ferrer-Gracia MC
  • Sarnago F
  • Alonso-Briales JH
  • Oteo JF
  • Serra V
  • Muntané-Carol G
  • Vilalta V
  • Del Val D
  • Pan M
  • García-Blas S
  • Díez JL
  • Berenguer A
  • Del Valle R
  • Navarro Del Amo F
  • Artaiz M
  • Regueiro A
  • López-Pérez M
  • Massó van-Roessel A
  • Paredes-Vázquez JG
  • Fernández-Cordón C
  • Diarte de Miguel JA
  • Maneiro N
  • Piserra-López A
  • de la Fuente J
  • Muñoz J
  • Romaguera R
  • Carrillo X
  • Alfonso F
  • Alvarado M
  • Millán X
  • Nombela-Franco L
  • Arzamendi D

Unidades

Abstract

BACKGROUND: Preexisting mitral prosthesis raises technical challenges for transcatheter aortic valve replacement (TAVR) but has been scarcely studied. This study sought to compare outcomes of patients with previous surgical mitral valve prostheses undergoing TAVR with balloon-expandable (BEV) or self-expanding valve (SEV) systems. METHODS: Patients from the Spanish TAVR registry with preexisting surgical mitral prostheses were included. The primary endpoints were Valve Academic Research Consortium-3 technical and device success and were analyzed according to valve type. The rates of transcatheter heart valve (THV) embolization, mitral valve impingement, THV performance and pacemaker were also assessed. RESULTS: A total of 243 patients were included (BEV: 37%; SEV: 63%). Overall technical success was 95.9%. 30-day device success was higher in BEV patients (94.4% vs 85.0%, p=0.036), mainly driven by lower incidences of moderate residual aortic regurgitation (0% vs 5.9%, p=0.028) and THV embolization (0% vs 3.9%, p=0.087). BEV recipients exhibited higher mean transvalvular gradients (10.5 vs 8.1 mmHg, p=0.002) and lower rates of permanent pacemaker implantation (5.6% vs 15.7%, p=0.023). There were no differences in mortality, bleeding or readmission at 30 days. In multivariate analysis, a mitroaortic distance =7 mm and lack of transesophageal echocardiography guidance were associated with increased device failure. CONCLUSIONS: In patients with preexisting MV prostheses, TAVR was safe and effective regardless of the THV type. Nevertheless, the use of BEVs resulted in a greater rate of device success driven by lesser THV embolization and residual aortic regurgitation.

Copyright © 2025. Published by Elsevier Inc.

Datos de la publicación

ISSN/ISSNe:
0828-282X, 1916-7075

CANADIAN JOURNAL OF CARDIOLOGY  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1480-1489
PubMed:
40345648

Citas Recibidas en Web of Science: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Cita

Compartir