Amphilimus-eluting versus zotarolimus-eluting stents in patients with diabetes mellitus and coronary artery disease: extended follow-up of the SUGAR randomised controlled trial.
Autores de IDIVAL
Autores ajenos al IDIVAL
- Salinas P
- Romaguera R
- Gómez-Lara J
- Brugaletta S
- Gómez-Menchero A
- Martín P
- Romero M
- García-Blas S
- Jiménez M
- Jiménez VA
- Bordes P
- Bayón J
- Salvatella N
- Alameda M
- Trillo-Nouche R
- López-Benito M
- Frutos A
- Moreu J
- García Del Blanco B
- Mohandes M
- Bosa Ojeda F
- Hernández Hernández F
- Pinar-Bermúdez E
- Jiménez-Quevedo P
- Rosselló X
- Pocock S
- Sabaté M
- Gómez-Hospital JA
- Comin-Colet J
- Gonzalo N
- Fernández Ortiz A
- SUGAR trial Investigators
Unidades
Abstract
BACKGROUND: Patients with diabetes mellitus (DM) have an elevated risk of late events after percutaneous coronary intervention (PCI). The Second-generation Drug-eluting Stents in Diabetes (SUGAR) trial (NCT03321032) compared amphilimus-eluting stents (AESs) and onyx-zotarolimus-eluting stents (O-ZESs) in this population. OBJECTIVES: To report the co-primary endpoint comparing target lesion failure (TLF) between AES and O-ZES at 2 years and the extended follow-up at 3 years. METHODS: The SUGAR trial enrolled 1175 patients with DM across 23 centres in a randomised (1:1 AES (Cre8EVO) or O-ZES (Resolute Onyx)) assessor-blinded design. The primary endpoint, assessed with a Cox proportional hazards model, was TLF (a composite of cardiac death, target vessel myocardial infarction or ischaemia-driven target lesion revascularisation). Secondary endpoints included all-cause mortality, stent thrombosis and major adverse cardiac events. RESULTS: At 2 years, TLF occurred in 60 (10.4%) patients in the AES group and 71 (12.1%) in the O-ZES group; HR 0.84 (95% CI 0.60 to 1.19), p=0.331. At 3 years, TLF occurred in 66 (11.4%) of the AES group compared with 87 (14.9%) of the O-ZES group (HR 0.77; 95% CI 0.56 to 1.06; p=0.106). Landmark analysis revealed no significant differences in TLF rates between 1 and 3 years (HR 1.07; 95% CI 0.62 to 1.87; p=0.801). Rates of individual components of the primary endpoint were comparable between groups. No significant differences were observed in secondary endpoints. CONCLUSIONS: The SUGAR trial demonstrates that AES and O-ZES provide comparable long-term efficacy in preventing TLF in patients with DM undergoing PCI. These findings support the use of either stent type and highlight the importance of further long-term studies to optimise outcomes. TRIAL REGISTRATION NUMBER: NCT03321032.
© Author(s) (or their employer(s)) 2025. No commercial re-use. See rights and permissions. Published by BMJ Group.
Datos de la publicación
- ISSN/ISSNe:
- 1355-6037, 1468-201X
- Tipo:
- Article
- Páginas:
- 1191-1198
- PubMed:
- 40562528
HEART BMJ PUBLISHING GROUP
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- Diabetes Mellitus; Percutaneous Coronary Intervention; Treatment Outcome
Campos de Estudio
Cita
Salinas P, Romaguera R, Gómez J, Brugaletta S, Gómez A, Martín P, Romero M, García S, Jiménez M, Jiménez VA, Bordes P, Bayón J, Salvatella N, Alameda M, Hyun D, Trillo R, López M, Frutos A, Moreu J, García Del Blanco B, Mohandes M, Bosa F, Hernández F, Pinar E, Jiménez P, Rosselló X, Pocock S, Sabaté M, Gómez JA, Comin J, Gonzalo N, Fernández A, SUGAR I. Amphilimus-eluting versus zotarolimus-eluting stents in patients with diabetes mellitus and coronary artery disease: extended follow-up of the SUGAR randomised controlled trial. Heart. 2025. 111. (24):p. 1191-1198. IF:4,400. (1).
Actividad Investigadora