Clinical Validation of AI-assisted Evaluation of Indeterminate Biliary Strictures in Digital-Single Operator Cholangioscopy: a Transcontinental Multicentric Study.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Mascarenhas M
- Widmer J
- Mendes F
- Ribeiro T
- Martins Pinto da Costa AM
- Agudo B
- Martins M
- Afonso J
- Mota J
- Almeida MJ
- Cardoso P
- Frias J
- Araújo C
- Cardoso H
- Plaza González M
- Pérez-González A
- Lera Dos Santos ME
- Garcia de Paredes AG
- Foruny J
- Bicudo de Oliveira L
- Ferreira de Carvalho M
- Maluf-Filho F
- Clara Ferreira M
- Prince T
- Velasquez A
- Enrique González I
- Ferreira J
- Kim GE
- Siddiqui UD
- Omrani LR
- Alrossais N
- Keegan M
- Aslam P
- Aggarwal V
- Vilas-Boas F
- Pereira P
- Sabbagh LC
- Almuhaidb A
- Guimarães Hourneaux De Moura E
- Macedo G
- González-Haba M
Unidades
Abstract
INTRODUCTION: Biliary strictures (BS) are a significant challenge, with malignant strictures frequently diagnosed at advanced stages, limiting curative options. Digital single-operator cholangioscopy (D-SOC) enables high-resolution, direct visualization of the bile duct, yet with suboptimal accuracy. Artificial intelligence (AI) has shown promise for detection and differentiation of BS in frame-level analysis and small clinical series. This study aimed to validate a deep learning model for AI-assisted D-SOC image analysis. METHODS: This multicenter study included 135 D-SOC exams from 129 patients (61 with malignant BS) across 14 centers in the United States, Brazil, Spain, Colombia, Australia, and Saudi Arabia. For each exam, up to 25 clinically relevant frames were selected and uploaded to a web-based platform for AI analysis. The model performed both detection and differentiation of BS: detection was assessed by comparing AI-generated bounding boxes with expert-defined annotations using intersection-over-union (IoU), while differentiation was benchmarked against histopathology. Performance metrics included accuracy, sensitivity, specificity, and positive and negative predictive values (PPV and NPV). RESULTS: At the patient level, malignant BS were identified with 86.0% accuracy, 84.1% sensitivity and 85.7% specificity, with an AUC of 0.904. The model demonstrated robust detection performance, achieving a mean IoU of 70.3%. Performance was maintained across demographic variables and centers. DISCUSSION: This first multicentric validation study demonstrates real-world performance of AI-assisted D-SOC analysis across multiples continents and devices, with robust accuracy for BS detection and differentiation. These findings support AI as an adjunctive tool in D-SOC, enhancing a more accurate evaluation of patients with indeterminate BS.
Copyright © 2026 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of The American College of Gastroenterology.
Datos de la publicación
- ISSN/ISSNe:
- 2155-384X, 2155-384X
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 41805080
Clinical and Translational Gastroenterology LIPPINCOTT WILLIAMS & WILKINS
Documentos
- No hay documentos
Filiaciones
Keywords
- Artificial Intelligence; Digital-Single Operator Cholangioscopy; Indeterminate Biliary Strictures
Cita
Mascarenhas M, Widmer J, Mendes F, Ribeiro T, Martins Pinto da Costa AM, Agudo B, Martins M, Afonso J, Mota J, Almeida MJ, Cardoso P, Frias J, Araújo C, Cardoso H, Plaza M, Pérez A, Lera Dos Santos ME, Moris M, Garcia de Paredes AG, Foruny J, Bicudo de Oliveira L, Ferreira de Carvalho M, Maluf F, Clara M, Prince T, Velasquez A, Enrique I, Ferreira J, Kim GE, Siddiqui UD, Omrani LR, Alrossais N, Keegan M, Aslam P, Aggarwal V, Vilas F, Pereira P, Sabbagh LC, Almuhaidb A, Guimarães Hourneaux De Moura E, Macedo G, González M. Clinical Validation of AI-assisted Evaluation of Indeterminate Biliary Strictures in Digital-Single Operator Cholangioscopy: a Transcontinental Multicentric Study. Clin. Transl. Gastroenterol. 2026. 17. (6):e01015. IF:3,600. (2).
Actividad Investigadora