Ultimaster TANSEI Stent in Complex Coronary Lesions: The EPIC08 TANSEI COMPLEX Study.
Fecha de publicación:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Palma-Carbajal, Ricardo
- Belahnech, Yassin
- Vegas Valle, Jose Miguel
- Rondan Murillo, Juan
- Menchero, Antonio-Gomez
- Perez de Prado, Armando
- Pinar Bermudez, Eduardo
- Martin Lorenzo, Pedro
- Jimenez Mazuecos, Jesus
- Garcia San Roman, Koldobika
- Vaquerizo, Beatriz
- Calvino Santos, Ramon
- Lozano Ruiz-Poveda, Fernando
- Ojeda Pineda, Soledad
- Perea Armijo, Jorge
- Bayon, Jeremias
- Goicolea Ruigomez, Javier
- Alonso Briales, Juan H
- Sanchis, Juan
- Garcia Del Blanco, Bruno
- and the EPIC08 TANSEI COMPLEX Study Group
Unidades
Abstract
Background: Percutaneous coronary intervention (PCI) for complex anatomy is increasingly common. The third-generation Ultimaster TANSEI drug-eluting stent (DES) was developed to optimise safety and efficacy in challenging lesions.; Methods: This was a prospective, single-arm, multicentre registry (August 2020-November 2022) of patients with complex lesions - left main, bifurcations, small vessels and long lesions - treated with Ultimaster TANSEI DES and followed for 1 year. The primary endpoint was the device-oriented composite endpoint (DoCE), including cardiac death, target-vessel MI, target-vessel revascularisation (TVR) and stent thrombosis. The secondary endpoint was the patient-oriented composite endpoint (PoCE), including all-cause death, any MI and any revascularisation.; Results: In total, 501 patients with 591 complex lesions (mean age 66.7 years; 79.6% male; 33.4% with diabetes) were treated. Lesion types: left main 11%, bifurcations 43.9%, small vessels 40.7%, long lesions 34.3%. At 1 year, incidence rates were: DoCE 3.23 per 100 person-years (95% CI [1.84-5.24]) and PoCE 5.04 per 100 person-years (95% CI [3.26-7.44]). In subgroup analyses, long lesions (>35 mm) showed consistently higher risk: DoCE RR 4.22 (95% CI [1.49-11.95]; p=0.006), PoCE RR 4.93 ([2.10-11.57]; p<0.001), overall mortality RR 4.79 [1.53-15.06]; p=0.007) and TVR RR 17.60 [2.22-139.51]; p<0.001). Copyright © The Author(s), 2026. Published by Radcliffe Group Ltd.
Datos de la publicación
- ISSN/ISSNe:
- 1756-1477, 1756-1485
- Tipo:
- Article
- Páginas:
- 9-9
- DOI:
- 10.15420/icr.2025.33
- PubMed:
- 42003940
Interventional Cardiology-Reviews Research Resources RADCLIFFE CARDIOLOGY
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- Clinical study, complex coronary lesions, drug-eluting stent, outcomes, percutaneous coronary intervention
Cita
Palma R, Belahnech Y, De La Torre JM, Garcia T, Vegas JM, Rondan J, Menchero A, Perez de Prado A, Pinar E, Martin P, Jimenez J, Garcia San Roman K, Vaquerizo B, Calvino R, Lozano Ruiz F, Ojeda S, Perea J, Bayon J, Goicolea J, Alonso JH, Sanchis J, Garcia Del Blanco B, and the EPIC08 TANSEI COMPLEX Study G. Ultimaster TANSEI Stent in Complex Coronary Lesions: The EPIC08 TANSEI COMPLEX Study. Interv. Cardiol.-Rev. Res. Resour. 2026. 21. p. 9-9. IF:2,000. (3).
Actividad Investigadora