Automated radiofrequency-based US measurement of common carotid intima-media thickness in RA patients treated with synthetic vs synthetic and biologic DMARDs
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Naredo, Esperanza
- Moeller, Ingrid
- Bong, David A.
- Cobo-Ibanez, Tatiana
- Corominas, Hector
- Luz Garcia-Vivar, Ma
- Macarron, Pilar
- Navio, Teresa
- Richi, Patricia
- Iagnocco, Annamaria
- Garrido, Jesus
- Martinez-Hernandez, David
Unidades
Abstract
Objective. To compare the carotid intima-media thickness (IMT) assessed with automated radiofrequency-based US in RA patients treated with synthetic vs synthetic and biologic DMARDs and controls. Methods. Ninety-four RA patients and 94 sex-and age-matched controls were prospectively recruited at seven centres. Cardiovascular (CV) risk factors and co-morbidities, RA characteristics and therapy were recorded. Common carotid artery (CCA)-IMT was assessed in RA patients and controls with automated radiofrequency-based US by the same investigator at each centre. Results. Forty-five (47.9%) RA patients had been treated with synthetic DMARDs and 49 (52.1%) with synthetic and biologic DMARDs. There were no significant differences between the RA patients and controls in demographics, CV co-morbidities and CV disease. There were significantly more smokers among RA patients treated with synthetic and biologic DMARDs (P = 0.036). Disease duration and duration of CS and synthetic DMARD therapy was significantly longer in RA patients treated with synthetic and biologic DMARDs (P<0.0005). The mean CCA-IMT was significantly greater in RA patients treated only with synthetic DMARDs than in controls [591.4 (98.6) vs 562.1 (85.8); P = 0.035] and in RA patients treated with synthetic and biologic DMARDs [591.4 (98.6) vs 558.8 (95.3); P = 0.040). There was no significant difference between the mean CCA-IMT in RA patients treated with synthetic and biologic DMARDs and controls (P = 0.997). Conclusion. Our results suggest that radiofrequency-based measurement of CCA-IMT can discriminate between RA patients treated with synthetic DMARDs vs RA patients treated with synthetic and biologic DMARDs.
Datos de la publicación
- ISSN/ISSNe:
- 1462-0324, 1462-0332
- Tipo:
- Article
- Páginas:
- 376-381
- PubMed:
- 23065319
RHEUMATOLOGY OXFORD UNIV PRESS
Citas Recibidas en Web of Science: 12
Documentos
- No hay documentos
Filiaciones
Keywords
- ultrasound; carotid intima-media thickness; rheumatoid arthritis; radiofrequency
Campos de Estudio
Cita
Naredo E, Moeller I, Corrales A, Bong DA, Cobo T, Corominas H, Luz Garcia MA, Macarron P, Navio T, Richi P, Iagnocco A, Garrido J, Martinez D. Automated radiofrequency-based US measurement of common carotid intima-media thickness in RA patients treated with synthetic vs synthetic and biologic DMARDs. RHEUMATOLOGY. 2013. 52. (2):p. 376-381. IF:4,212. (1).
Actividad Investigadora