Prospective Multicenter Study of the Low-Profile Relay Stent-Graft in Patients with Thoracic Aortic Disease: The Regeneration Study
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Riambau V
- Giudice R
- Trabattoni P
- Llagostera S
- Fadda G
- Lenti M
- Maeso J
- Blanco C
- Verzini F
Unidades
Abstract
Background: To evaluate the early safety and clinical performance of the new low-profile RelayPro Thoracic Stent-Graft System in patients with thoracic aortic disease. Methods: This was an international, prospective, single-arm study in patients diagnosed with thoracic aorta disease (aneurysm, pseudoaneurysm, dissection, penetrating atherosclerotic ulcer, or intramural hematoma) and treated with a RelayPro stent-graft (in bare stent and/or nonbare stent configurations). The primary endpoints were freedom from aneurysm or dissectionrelated mortality and stent-graft performance. Results: A total of 31 patients were treated with the RelayPro thoracic stent-graft between 2014 and 2015 at 8 sites in Italy and Spain. Mean age was 72.1 (+/- 10.2) years and 77% were male, 74% with hypertension, and 42% with a history of smoking. Twenty-four (77%) had aneurysms (fusiform in 46%, saccular in 42%, pseudoaneurysm in 12%); 5 (16%) had penetrating atherosclerotic ulcer; and 2 (6%) had chronic Type B dissection. Mean vascular access diameter was 9.1 mm (6-13 mm); 7 patients (23%) had vascular access of 7 mm or less. Technical success was 100% (primary, 90%; assisted primary, 10%). Freedom from aneurysm/dissection-related mortality through 30 days was 100%. Freedom from device-related major adverse events through 30 days was 94%. At 1 year, there was 1 (3%) type Ib and 1 (3%) type II endoleak, 1 (3%) nonaneurysm-related late death, and 1 (3%) secondary intervention (to correct type Ib endoleak). Conclusions: The RelayPro has a 3-4 French profile reduction to allow endovascular repair of thoracic aortic disease in patients with smaller anatomies. This study shows good initial stent-graft performance and a favorable early safety profile.
Datos de la publicación
- ISSN/ISSNe:
- 0890-5096, 1615-5947
- Tipo:
- Article
- Páginas:
- 180-189
- PubMed:
- 30684621
ANNALS OF VASCULAR SURGERY ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 17
Documentos
Filiaciones
Campos de Estudio
Cita
Riambau V, Giudice R, Trabattoni P, Llagostera S, Fadda G, Lenti M, García I, Maeso J, Blanco C, Verzini F. Prospective Multicenter Study of the Low-Profile Relay Stent-Graft in Patients with Thoracic Aortic Disease: The Regeneration Study. Ann. Vasc. Surg. 2019. 58. p. 180-189. IF:1,179. (3).
Actividad Investigadora