Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Cantón R
- Oliver A
- Alós JI
- de Benito N
- Bou G
- Campos J
- Canut A
- Castillo J
- Cercenado E
- Domínguez MÁ
- Fernández-Cuenca F
- Guinea J
- Larrosa N
- Liñares J
- López-Cerero L
- López-Navas A
- Marco F
- Mirelis B
- Moreno-Romo MÁ
- Morosini MI
- Navarro F
- Oteo J
- Pascual Á
- Pérez-Trallero E
- Pérez-Vázquez M
- Soriano A
- Torres C
- Vila J
- Martínez-Martínez L
Unidades
Abstract
Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee (Comite Espanol del Antibiograma, COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs. (C) 2019 Elsevier Espana, S.L.U. and Sociedad Espanola de Enfermedades Infecciosas y Microbiologia Clinica. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0213-005X, 1578-1852
- Tipo:
- Review
- Páginas:
- 182-187
- PubMed:
- 30878313
- Enlace a otro recurso:
- www.sciencedirect.com
ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA EDICIONES DOYMA S A
Citas Recibidas en Web of Science: 6
Documentos
- No hay documentos
Filiaciones
Keywords
- Antibiogram; Automated susceptibility testing systems; Minimum antimicrobial concentrations; MICs; Antibiograma; Sistemas automáticos de detección de sensibilidad; Concentraciones mínimas antimicrobianas; CMI
Campos de Estudio
Cita
Cantón R, Oliver A, Alós JI, de Benito N, Bou G, Campos J, Calvo J, Canut A, Castillo J, Cercenado E, Domínguez MÁ, Fernández F, Guinea J, Larrosa N, Liñares J, López L, López A, Marco F, Mirelis B, Moreno MÁ, Morosini MI, Navarro F, Oteo J, Pascual Á, Pérez E, Pérez M, Soriano A, Torres C, Vila J, Martínez L. Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for <i>in vitro</i> susceptibility studies using automated systems. Enferm. Infec. Microbiol. Clin. 2020. 38(4):p. 182-187. IF:1,654. (4).
Actividad Investigadora