Infective endocarditis in patients with cardiac implantable electronic devices: a nationwide study

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Mateos Gaitán R
  • Boix-Palop L
  • Muñoz García P
  • Mestres CA
  • Marín Arriaza M
  • Pedraz Prieto Á
  • de Alarcón Gonzalez A
  • Gutiérrez Carretero E
  • Hernández Meneses M
  • Goenaga Sánchez MÁ
  • Oteo Revuelta JA
  • Gainzarain Arana JC
  • García Vázquez E
  • Martínez-Sellés M

Unidades

Abstract

Aims Patients with infective endocarditis (IE) frequently have cardiac implantable electronic devices (CIEDs). Here, we aim to define the clinical profile and prognostic factors of IE in these patients. Methods and results Infective endocarditis cases were prospectively identified in the Spanish National Endocarditis Registry. From 3996 IE, 708 (17.7%) had a CIED and 424 CIED-related IE (lead vegetation). Patients with a CIED were older (6811 vs. 73 +/- 8years); had more comorbidities {pulmonary disease [176 (24.8%) vs. 545 (16.7%)], renal disease [239 (33.8%) vs. 740 (22.7%)], diabetes [248 (35.0%) vs. 867 (26.6%)], and heart failure [348 (49.2%) vs. 978 (29.9%)]}; and fewer complications {intracardiac destruction [106 (15%) vs. 1077 (33.1%)], heart failure [215 (30.3%) vs. 1340 (41.1%)], embolism [107 (15.1%) vs. 714 (21.9%)], and neurological involvement [77 (10.8%) vs. 702 (21.5%)]} (all P-values <0.001) in comparison to subjects without a CIED. In-hospital mortality was similar in patients with and without CIED [171 (24.2%) vs. 881 (27.0%), P=0.82]. In subjects with a CIED, CIED-related IE was independently associated with in-hospital survival: odds ratio (OR) 0.4 [95% confidence interval (CI) 0.3-0.7, P=0.001]. Surgery was independently associated with in-hospital survival in CIED-related IE: OR 0.4 (95% CI 0.2-0.7, P=0.004); but not in subjects with valve IE and no CIED lead involvement: OR 0.9 (95% CI 0.5-1.7, P=0.77). Conclusion Over a sixth of IE patients have a CIED. This group of patients is older, with more comorbidities and fewer IE-related complications in comparison to subjects without a CIED. In-hospital mortality was similar in patients with and without a CIED.

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.

Datos de la publicación

ISSN/ISSNe:
1099-5129, 1532-2092

EUROPACE  OXFORD UNIV PRESS

Tipo:
Article
Páginas:
1062-1070
PubMed:
32390046

Citas Recibidas en Web of Science: 48

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Cardiac implantable electronic device; Cardiac surgery; Device infection; Infective endocarditis