High accuracy of spleen stiffness measurement in diagnosing clinically significant portal hypertension in metabolic-associated fatty liver disease
Autores de IDIVAL
Unidades
Abstract
Background and AimsSpleen stiffness measurement (SSM) by vibration-controlled transient elastography (VCTE) has been tested in a limited number of studies versus hepatic venous pressure gradient (HVPG), especially with the 100 Hz spleen-specific module. The current study aims to evaluate the diagnostic performance of this novel module for detecting clinically significant portal hypertension (CSPH) in a cohort of compensated patients with metabolic-associated fatty liver disease (MAFLD) as the main aetiology and to improve the performance of the Baveno VII criteria for CSPH diagnosis by including SSM. MethodsThis is a retrospective single-centre study including patients with available measurements of HVPG, Liver stiffness measurement (LSM) and SSM by VCTE with the 100 Hz module. Area under the receiver operating characteristic (AUROC) curve analysis was conducted to identify dual cut-offs (rule-out and rule-in) associated with the absence/presence of CSPH. The diagnostic algorithms were adequate if negative predictive value (NPV) and positive predictive values (PPV) were >90%. ResultsA total of 85 patients were included, 60 MAFLD and 25 non-MAFLD. SSM showed a good correlation with HVPG (MAFLD: r = .74; p < .0001; non-MAFLD: r = .62; p < .0011). In MAFLD patients, SSM had a high accuracy in discarding/diagnosing CSPH (cut-off values of 49.9 kPa, AUC 0.95). The addition of these cut-offs in a sequential or combined approach to the Baveno VII criteria significantly reduced the grey zone (60% vs. 15%-20%), while maintaining adequate NPV and PPV. ConclusionsOur findings support the utility of SSM for diagnosing CSPH in MAFLD patients and demonstrate that the addition of SSM to the Baveno VII criteria increases accuracy.
© 2023 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Datos de la publicación
- ISSN/ISSNe:
- 1478-3223, 1478-3231
- Tipo:
- Article
- Páginas:
- 1446-1457
- DOI:
- 10.1111/liv.15561
- PubMed:
- 36912787
LIVER INTERNATIONAL WILEY
Citas Recibidas en Web of Science: 24
Documentos
- No hay documentos
Filiaciones
Keywords
- cirrhosis; liver stiffness; portal hypertension; spleen stiffness; transient elastography
Campos de Estudio
Cita
Odriozola A, Puente Á, Cuadrado A, Iruzubieta P, Arias MT, Redondo C, Rivas C, Fábrega E, Crespo J, Fortea JI. High accuracy of spleen stiffness measurement in diagnosing clinically significant portal hypertension in metabolic-associated fatty liver disease. Liver Int. 2023. 43. (7):p. 1446-1457. IF:6,700. (1).
Actividad Investigadora