Total error in lymphocyte subpopulations by flow cytometry-based in state of the art using Spanish EQAS data

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • Alejandra Comins Boo

    Autor

  • Juan Irure Ventura

    Autor

  • Marcos López Hoyos

    Autor

  • David San Segundo Arribas

    Autor

Autores ajenos al IDIVAL

  • Pérez-Pla F
  • Blanco-Peris L
  • Martín Alonso MDC

Unidades

Abstract

Objectives: Flow cytometry analyses of lymphocyte subpopulations (T, B, NK) are crucial for enhancing clinical algorithms and research workflows. Estimating the total error (TE) values for the percentage and absolute number of lymphocyte subpopulations using the state-of-the-art (SOTA) approach with real data from an external proficiency testing (EPT) scheme was performed. A comparison with previously published Biological Variability (BV)-based specifications was carried out. Methods: A total of 44,998 results from 86 laboratories over 10 years were analysed and divided into two five-year periods (2012-2016) and (2017-2021). Data come from the IC-1 Lymphocytes scheme of the Spanish External Quality Assurance System (EQAS) GECLID Program. This quantitative scheme includes percentages and absolute numbers of CD3(+), CD3(+)CD4(+), CD3(+)CD8(+), CD19(+), and CD3-CD56(+)CD16(+) NK cells. The percentage of TE was calculated as: |reported value - robust mean|*100/robust mean for each laboratory and parameter. The cut-off for TE is set at 80% best results of the laboratories. Results: A significant reduction in the SOTA-based TE for all lymphocyte subpopulations in 2017-2021 was observed compared to 2012-2016. The SOTA-based TE fulfils the minimum BV-based TE for percentages of lymphocyte subpopulations. The parameter with the best analytical performance calculated with SOTA (2017-2021 period)-based TE was the percentage of CD3(+) (TE=3.65 %). Conclusions: The values of SOTA-based specifications from external quality assurance program data are consistent and can be used to develop technical specifications. The technological improvement, quality commitment, standardization, and training, reduce TE. An update of TE every five years is therefore recommended. TE assessment in lymphocyte subsets is a helpful and reliable tool to improve laboratory performance and data-based decision-making trust.

© 2023 Walter de Gruyter GmbH, Berlin/Boston.

Datos de la publicación

ISSN/ISSNe:
1434-6621, 1437-4331

CLINICAL CHEMISTRY AND LABORATORY MEDICINE  WALTER DE GRUYTER GMBH

Tipo:
Article
Páginas:
312-321
PubMed:
37548423

Citas Recibidas en Web of Science: 9

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • ISO15189; allowable total error; biological variability; lymphocyte subsets; proficiency testing

Cita

Compartir