Critical comparison of ELISA kits for CGRP measurements in migraine.

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Unidades

Abstract

OBJECTIVES/BACKGROUND: Our aim was to compare the performance of commercially available enzyme-linked immunosorbent assay (ELISA) kits for detecting mature a- and ß-calcitonin gene-related peptide (CGRP) isoforms and test the hypothesis of a potential lack of reliability. CGRP is one of the most extensively studied biomarkers in migraine, but the reliability of commercially available ELISA assays for its measurement remains controversial. METHODS: In this method comparison study, we analyzed serum samples from 19 patients with migraine in Marqués de Valdecilla University Hospital, along with synthetic peptide samples (a- and ß-CGRP), including preparations of each isoform at different concentrations. The following ELISA kits were evaluated according to the manufacturers' instructions: one kit theoretically specific for a-CGRP (abx252189, Abbexa, Kit B); and three kits considered specific for ß-CGRP (CSB-E08210h, CUSABIO, Kit C; abx151047, Abbexa, Kit D; and abx514274, Abbexa, Kit E). In addition, Bertin assay (A05481.96), Kit A, designed to detect both CGRP isoforms, was assessed. RESULTS: Kit A was the only kit capable of detecting the synthetic peptide in both isoforms and demonstrated a measurable positive relationship of nominal versus observed levels. In contrast, the remaining kits, theoretically specific for a single isoform, failed to detect the corresponding synthetic peptide. Quantification of CGRP levels in 19 patient samples showed no significant correlation among the assays. No correlation was found among the three different assays targeting ß-CGRP. Intrakit variability was acceptable for all kits tested. CONCLUSION: These findings indicate that the ELISA assays tested, designed to measure specific isoforms of mature CGRP isoforms, are unable to detect the synthetic peptide. Nevertheless, it is possible that these assays quantify other CALCA/CALCB-derived products that may retain biological activity in patients with migraine. The absence of correlation among kits targeting the ß-CGRP isoform further suggests differences among kits, which might be due to differences in calibration, cross-reactivity, noise, or the use of different antigens, raising the possibility that the kits detect different CGRP-related forms, including precursor/propeptide and other processed forms.

© 2026 The Author(s). Headache: The Journal of Head and Face Pain published by Wiley Periodicals LLC on behalf of American Headache Society.

Datos de la publicación

ISSN/ISSNe:
0017-8748, 1526-4610

HEADACHE  WILEY

Tipo:
Article
Páginas:
-
PubMed:
42985926

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • calcitonin gene-related peptide; enzyme-linked immunosorbent assay kits; isoforms; migraine

Cita

Compartir