Allowable total error in CD34 cell analysis by flow cytometry based on state of the art using Spanish EQAS data

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

  • Sara Fernández Luis

    Autor

  • Alejandra Comins Boo

    Autor

  • Juan Irure Ventura

    Autor

  • Andrés Insunza Gaminde

    Autor

  • Marcos López Hoyos

    Autor

  • David San Segundo Arribas

    Autor

Autores ajenos al IDIVAL

  • Perez-Pla, Fernando
  • Blanco-Peris, Lydia
  • Martin Alonso, M Carmen

Unidades

Abstract

Objectives: CD34+ hematopoietic stem cell (HSC) enumeration, crucial for HSC transplantation, is performed by flow cytometry to guide clinical decisions. Variability in enumeration arises from biological factors, assay components, and technology. External quality assurance schemes (EQAS) train participants to minimize inter-laboratory variations. The goal is to estimate total error (TE) values for CD34 cell enumeration using state-of-the-art (SOTA) methods with EQA data and to define quality specifications by comparing TE using different cutoffs. Methods: A total of 3,994 results from 40 laboratories were collected over 11 years (2011-2022) as part of the IC-2 Stem Cells Scheme of the GECLID Program that includes absolute numbers of CD34 cells. The data were analyzed in two periods: 2011-2016 and 2017-2022. The TE value achieved by at least 60 %, 70 %, 80 %, and 90 % of laboratories was calculated across the two different periods and at various levels of CD34 cell counts: above 25, 25 to 15, and under 15 cells/mu L. Results: A decrease in the SOTA-based TE for CD34 cell enumeration was observed in the most recent period in 2017-2021 compared with 2012-2016. A significant increase of P75 TE values in the low CD34 range (<15 cells/mu L) levels was found (p<0.001). Conclusions: Technical advancements contribute to the decrease TE over time. The TE of CD34 cell FC counts is measure-dependent, making it responsive to precision enhancement strategies. The TE measured by EQAS in this study may serve as a quality specification for implementing ISO 15189 standards in clinical laboratories for CD34 cell enumeration.

Datos de la publicación

ISSN/ISSNe:
1434-6621, 1437-4331

CLINICAL CHEMISTRY AND LABORATORY MEDICINE  WALTER DE GRUYTER GMBH

Tipo:
Article
Páginas:
367-375
PubMed:
39543980

Citas Recibidas en Web of Science: 4

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • biological variability; allowable total error; CD34; proficiency testing; ISO15189; stem cells