Validation of 2 Prognostic Models to Predict Renal Allograft Outcome After IgA Nephropathy Recurrence.
Fecha de publicación:
Fecha Ahead of Print:
Autores de IDIVAL
Autores ajenos al IDIVAL
- Quintana LF
- Vázquez-Sánchez T
- Sánchez-Fructuoso A
- Buxeda A
- Gavela E
- Cazorla JM
- Cabello S
- Beneyto I
- Sevillano AM
- López-Oliva MO
- Diekmann F
- Gómez-Ortega JM
- Calvo-Romero N
- Pérez-Sáez MJ
- Sancho A
- Mazuecos A
- Espí-Reig J
- Trujillo H
- Jiménez C
- Hernández D
Unidades
Abstract
INTRODUCTION: IgA nephropathy (IgAN) recurrence (IgANr) after kidney transplantation (KTx) is common and contributes to reducing graft survival. Some tools have been developed to predict the patients who are at a higher risk of poor outcomes among the native (international IgAN prediction tool [IIgAN-PT]) and graft (Bednarova's prediction tool [Bednarova-PT]) kidney. We aimed to analyze their performance in a KTx population other than the originally reported. METHODS: We performed a multicenter retrospective study including KTx with biopsy-proven IgANr. IIgAN-PT and Bednarova-PT were used to calculate the risk of death-censored graft loss (DCGL). We assessed the performance of both prediction models using discrimination and calibration metrics and Kaplan-Meier plots. RESULTS: One hundred twenty KTx with IgANr were included. The time-dependent receiver operating characteristic (ROC) area under the curve (AUC) of Bednarova-PT for predicting DCGL was 83.5 (95% CI: 72.3-94.7) and the calibration slope was 0.96 (95% CI: 0.37-1.49). The time-dependent ROC AUC of IIgAN-PT for predicting DCGL was 87.3 (95% CI: 77.58-97.02) and the calibration slope was 2.49 (95% CI: 0.19-4.13). IIgAN-PT tended to underestimate the graft-loss risk in high-risk individuals. The Kaplan-Meier curve of the highest risk group, defined by using both prediction tools, was clearly separated from the other curves. CONCLUSION: Both IIgAN-PT and Bednarova-PT performed well in predicting DCGL after IgANr and should be used to identify those KTx at the highest risk. Both models had good discriminatory ability and were well-calibrated, although the calibration slope was higher for IIgAN-PT, tending to underestimate the risk in high-risk individuals.
© 2025 International Society of Nephrology. Published by Elsevier Inc.
Datos de la publicación
- ISSN/ISSNe:
- 2468-0249, 2468-0249
- Tipo:
- Article
- Páginas:
- 2323-2333
- PubMed:
- 40677345
Kidney International Reports ELSEVIER SCIENCE INC
Documentos
- No hay documentos
Filiaciones
Keywords
- IgA nephropathy; crescents; graft loss; inflammation; kidney transplantation; prediction tools; recurrence
Campos de Estudio
Proyectos asociados
Post-transplant changes in follicular helper T cells analyzed by a comprehensive assessment of the risk factors of developing "de novo" donor-specific antibodies.
Investigador Principal: Emilio Rodrigo Calabia
RD24/0004/0019 . INSTITUTO DE SALUD CARLOS III. . 2025
Cita
Rodrigo E, Quintana LF, Vázquez T, Sánchez A, Buxeda A, Gavela E, Cazorla JM, Cabello S, Beneyto I, Sevillano AM, López MO, Diekmann F, Gómez JM, Calvo N, Pérez MJ, Sancho A, Mazuecos A, Espí J, Trujillo H, Jiménez C, Hernández D. Validation of 2 Prognostic Models to Predict Renal Allograft Outcome After IgA Nephropathy Recurrence. Kidney Int. Rep. 2025. 10. (7):p. 2323-2333. IF:5,700. (1).
Actividad Investigadora