Vitamin D nutritional status and vitamin D regulated antimicrobial peptides in serum and pleural fluid of patients with infectious and noninfectious pleural effusions

Fecha de publicación: Fecha Ahead of Print:

Autores de IDIVAL

Autores ajenos al IDIVAL

  • Santos, F
  • Ortiz, M

Unidades

Abstract

Background: Vitamin D and vitamin D dependent antimicrobial peptides such as Cathelicidin (LL-37) and beta-defensin 2 have an important role in innate and adaptative immunity, but their role in pleural effusions has not been studied before. Methods: Serum and pleural fluid samples from 152 patients with pleural effusion were collected, corresponding to 45 transudates and 107 exudates, 51 infectious effusions (14 complicated and 37 non-complicated), 44 congestive heart failure effusions and 38 malignant effusions. The levels of 25 OH-vitamin D, 1,25-(OH) 2-vitamin D, Vitamin D Binding Protein (VDBP), LL-37 and beta-defensin 2, both in serum and pleural fluid were evaluated in this prospective study. Differences between groups were analysed using unpaired t tests or Mann-Whitney tests. Correlations between data sets were examined using Pearson correlation coefficient or Spearman rank correlation coefficient. Diagnostic accuracy was estimated using ROC curve analysis. Results: Low serum 25 OH vitamin D levels were found in all groups. Infectious effusions (IE) had higher serum and pleural fluid LL-37 levels compared to congestive heart failure or malignant effusions. Among IE, complicated had higher serum and pleural fluid LL-37 levels, and lower serum beta-defensin-2 levels. Positive correlations were found between serum 25 OH-vitamin D levels and serum or pleural 1,25-(OH) 2-vitamin D levels, and between 1,25-(OH) 2-vitamin D and LL-37 serum. Diagnostic accuracy of the different molecules was moderate at best. Conclusions: Hypovitaminosis D is highly prevalent in pleural effusions. LL-37 is produced intrapleurally in IE. This production is higher in complicated IE. No evidence of pleural production of beta-defensin 2 was found in any of the groups. Diagnostic accuracy of the different molecules is at the best moderate for discriminating different types of effusions.

Datos de la publicación

ISSN/ISSNe:
1471-2466, 1471-2466

BMC Pulmonary Medicine  BMC

Tipo:
Article
Páginas:
99-99
PubMed:
27392908

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Pleural effusion; LL-37; Cathelicidin; beta-defensin-2; 25 OH vitamin D

Campos de Estudio

Cita

Compartir